MAX4889 Maxim, MAX4889 Datasheet - Page 6
MAX4889
Manufacturer Part Number
MAX4889
Description
The MAX4888/MAX4889 high-speed passive switches route PCI Express® (PCIe) data between two possible destinations
Manufacturer
Maxim
Datasheet
1.MAX4888.pdf
(16 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
MAX4889AETO+
Manufacturer:
Maxim
Quantity:
1 475
Company:
Part Number:
MAX4889ETO+
Manufacturer:
Maxim
Quantity:
215
Company:
Part Number:
MAX4889ETO+T
Manufacturer:
DALLAS
Quantity:
2 061
2.5Gbps PCI Express Passive Switches
6
1, 10, 12, 14,
8, 11, 13, 19,
MAX4888
20, 25, 27
_______________________________________________________________________________________
26, 28
3, 9
EP
15
16
17
18
21
22
23
24
—
—
—
—
—
—
—
—
—
—
—
—
2
4
5
6
7
PIN
1, 4, 10, 14, 17,
19, 21, 39, 41
5, 8, 13, 18,
MAX4889
20, 30,
40, 42
31
32
33
34
35
36
37
38
11
12
15
16
22
23
24
25
26
27
28
29
EP
—
9
2
3
6
7
COM1+
COM2+
COM3+
COM4+
COM1-
COM2-
COM3-
COM4-
NAME
NO2+
NO1+
NO4+
NO3+
NC2+
NC1+
NC4+
NC3+
NO2-
NO1-
NC2-
NC1-
NO4-
NO3-
NC4-
NC3-
GND
N.C.
SEL
V+
EP
Ground
Digital Control Input
No Connection. Not internally connected.
Analog Switch 1. Common Positive Terminal.
Analog Switch 1. Common Negative Terminal.
Analog Switch 2. Common Positive Terminal.
Analog Switch 2. Common Negative Terminal.
Positive-Supply Voltage Input. Connect V+ to a 1.65V to 3.6V supply voltage.
Bypass V+ to GND with a 0.1µF capacitor placed as close to the device as possible.
(See the Board Layout section).
Analog Switch 2. Normally Open Negative Terminal.
Analog Switch 2. Normally Open Positive Terminal.
Analog Switch 1. Normally Open Negative Terminal.
Analog Switch 1. Normally Open Positive Terminal.
Analog Switch 2. Normally Closed Negative Terminal.
Analog Switch 2. Normally Closed Positive Terminal.
Analog Switch 1. Normally Closed Negative Terminal.
Analog Switch 1. Normally Closed Positive Terminal.
Analog Switch 3. Common Positive Terminal.
Analog Switch 3. Common Negative Terminal.
Analog Switch 4. Common Positive Terminal.
Analog Switch 4. Common Negative Terminal.
Analog Switch 4. Normally Open Negative Terminal.
Analog Switch 4. Normally Open Positive Terminal.
Analog Switch 3. Normally Open Negative Terminal.
Analog Switch 3. Normally Open Positive Terminal.
Analog Switch 4. Normally Closed Negative Terminal.
Analog Switch 4. Normally Closed Positive Terminal.
Analog Switch 3. Normally Closed Negative Terminal.
Analog Switch 3. Normally Closed Positive Terminal.
Exposed Paddle. Connect EP to GND.
FUNCTION
Pin Description