Smart Highside Power Switch Features Overload protection Current limitation Short circuit protection Thermal shutdown Overvoltage protection (including load dump) Fast demagnetization of inductive loads 1 ) Reverse battery protection Undervoltage and overvoltage shutdown with auto-restart and hysteresis Open drain diagnostic ...
Page 2
Pin Symbol 1 GND - OUT O (Load, L) Maximum Ratings °C unless otherwise specified j Parameter Supply voltage (overvoltage protection see page 3) ) ...
Page 3
Electrical Characteristics Parameter and Conditions ° unless otherwise specified j bb Load Switching Capabilities and Characteristics On-state resistance (pin 1 Nominal load current, ISO Norm ...
Page 4
Parameter and Conditions ° unless otherwise specified j bb Protection Functions 9) Initial peak short circuit current limit (pin max 450 > ON(SC) ...
Page 5
Parameter and Conditions ° unless otherwise specified j bb Input and Status Feedback Input turn-on threshold voltage Input turn-off threshold voltage Input threshold hysteresis Off state input current (pin 2 ...
Page 6
Truth Table Input- Output level level Normal L L operation H H Open load Short circuit GND H L Short circuit Overtem perature ...
Page 7
Status output R ST(ON) GND ESD-Zener diode typ., max 5 mA; R < 250 at 1.6 mA, ESD zener diodes are not ST(ON used as voltage clamp at DC conditions. Operation in this mode may result ...
Page 8
GND disconnect with GND pull PROFET ST 4 GND GND bb Any kind of load device stays off GND > IN IN(T+) ...
Page 9
Typ. transient thermal impedance chip case Z = f(t , D), D=t /T thJC [K/W] thJC 10 1 0.1 0.01 1E-5 1E-4 1E-3 1E-2 Semiconductor Group D= 0.5 0.2 0.1 0.05 0.02 0.01 0 1E-1 1E0 1E1 ...
Page 10
Options Overview all versions: High-side switch, Input protection, ESD protection, load dump and reverse battery protection with 150 ground Type Logic version Overtemperature protection with hysteresis T j >150 °C, latch function >150 °C, ...
Page 11
Timing diagrams Figure 1a: V turn on d(bb IN OUT A ST open drain A in case of too early V IN =high the device may not turn on (curve A) t approx. 150 ...
Page 12
Figure 3b: Turn on into overload L(SCp) I L(SCr) ST Heating up may require several seconds < 8.5 V typ. bb OUT Figure 3c: Short circuit while on OUT I ...
Page 13
Figure 5b: Open load: detection in ON-state, open load occurs in on-state IN t d(ST OL1 OUT normal open tbd s typ tbd s typ d(ST OL1) d(ST OL2) Figure 6a: Undervoltage: ...
Page 14
Figure 9a: Overvoltage at short circuit shutdown bb(o rst) Output short to GND V OUT short circuit shutdown Overvoltage due to power line inductance. No overvoltage auto- restart of PROFET after short circuit ...
Page 15
... All dimensions in mm Standard TO-220AB/5 BTS 410 E2 Q67060-S6102-A2 TO-220AB/5, Option E3043 BTS 410 E2 E3043 Q67060-S6102-A3 Semiconductor Group SMD TO-220AB/5, Opt. E3062 Ordering code BTS410E2 E3062A T&R: Changed since 04.96 Date Change Mar. E 1997 and Z ESD capability (except Input) Ordering code specified to 2kV, R ...
Page 16
... Due to technical requirements components may contain dangerous substances. For information on the types in question please contact your nearest Infineon Technologies Office. Infineon Technologies Components may only be used in life- support devices or systems with the express written approval of Infineon Technologies failure of such components can reasonably be expected to cause the failure of that life-support device or system affect the safety or effectiveness of that device or system ...