Description
RAD TOLERANT, HIGH SPEED, BUFFER AMPLIFIER
Manufacturer
M.S. Kennedy Corp.
Datasheet
4707 Dey Road Liverpool, N.Y. 13088
FEATURES:
DESCRIPTION:
LH0002. The device is ideal for use with an operational amplifier in a closed loop configuration to increase current
output. The MSK 0002RH is designed with a symmetrical output stage that provides low output impedances to both
the positive and negative portions of output pulses. The MSK 0002RH is packaged in a hermetic 8 lead low profile
T0-5 header and is specified over the full military temperature range.
MIL-PRF-38534 CERTIFIED
Total Dose Tested to 300 Krads (Si)
RAD Tolerant LH0002 Replacement
High Input Impedance-180K
Low Output Impedance-10
Low Harmonic Distortion
DC to 30 MHz Bandwidth
Slew Rate is Typically 400 V/µS
Operating Range from±5V to ±20V
Contact MSK for MIL-PRF-38534 Qualification Status and Appendix G (Radiation Status)
High Speed D/A Conversion
30MHz Buffer
Line Driver
Precision Current Source
The MSK 0002RH is a general purpose current amplifier. It is the industry wide RAD tolerant replacement for the
M.S.KENNEDY CORP.
EQUIVALENT SCHEMATIC
TYPICAL APPLICATIONS
Max
Min
BUFFER AMPLIFIER
RAD TOLERANT,
HIGH SPEED,
1
1
2
3
4
PIN-OUT INFORMATION
V1+
V2+
E3
Output
0002RH
5
6
7
8
E4
V2-
V1-
Input
(315) 701-6751
Rev. A 4/07

Related parts for MSK0002KRH

MSK0002KRH Summary of contents

Page 1

MIL-PRF-38534 CERTIFIED M.S.KENNEDY CORP. 4707 Dey Road Liverpool, N.Y. 13088 FEATURES: Total Dose Tested to 300 Krads (Si) RAD Tolerant LH0002 Replacement High Input Impedance-180K Min Low Output Impedance-10 Max Low Harmonic Distortion MHz Bandwidth Slew Rate ...

Page 2

ABSOLUTE MAXIMUM RATINGS ±V Supply Voltage CC V Input Voltage IN P Power Dissipation d Tc Case Operating Temperature (MSK 0002K/H/E RH) (MSK 0002RH) ELECTRICAL SPECIFICATIONS Parameter Quiescent Current Input Current Output Offset Voltage V IN Input Impedance 3 V ...

Page 3

APPLICATION NOTES HEAT SINKING To determine if a heat sink is necessary for your application and if so, what type, refer to the thermal model and governing equation below. Thermal Model: Governing Equation ...

Page 4

TYPICAL PERFORMANCE CURVES 4 Rev. A 4/07 ...

Page 5

RADIATION CURVES NOTE: All radiation curve test conditions are in accordance with the electrical specifications table (page 2). See RAD report for bias and dose rate. 5 Rev. A 4/07 ...

Page 6

RADIATION CURVES CONT'D NOTE: All radiation curve test conditions are in accordance with the electrical specifications table (page 2). See RAD report for bias and dose rate. 6 Rev. A 4/07 ...

Page 7

... MSK0002RH MSK0002ERH MSK0002HRH MSK0002KRH 4707 Dey Road, Liverpool, New York 13088 The information contained herein is believed to be accurate at the time of printing. MSK reserves the right to make changes to its products or specifications without notice, however, and assumes no liability for the use of its products. ...