VSD-50 CUI INC, VSD-50 Datasheet

no-image

VSD-50

Manufacturer Part Number
VSD-50
Description
Vsd-50 Series Single Output Dc-dc Converter
Manufacturer
CUI INC
Datasheet
Features
·2:1 wide input range
·Short circuit, overload, over-voltage
·1500VDC I/O isolation
·Built in EMI filter, low ripple noise
·Fixed switching frequency at 83KHz
·100% full load burn-in test
·Low cost, high reliability
·1 year warranty
·50 watts
protected
Notes:
Model 1,3
VSD-50A-5
VSD-50A-12
VSD-50A-24
VSD-50B-5
VSD-50B-12
VSD-50B-24
VSD-50C-5
VSD-50C-12
VSD-50C-24
1 All parameters Not specifically mentioned are measured at normal input, rated load and 25ºC of ambient temp.
2 Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uF
3 The power supply is considered a component which will be installed into final equipment. The final equipment
& 47uF parallel capacitor.
must be re-confirmed that it still meets EMC directives.
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062
9.2~18V DC
19~36V DC
36~72V DC
9.2~18V DC
9.2~18V DC
19~36V DC
36~72V DC
19~36V DC
36~72V DC
Voltage
Input
Voltage
12V DC
24V DC
12V DC
24V DC
12V DC
24V DC
Output
5V DC
5V DC
5V DC
VSD-50 Series Single Output DC-DC Converter
Current
Output
4.2 A
2.1 A
4.2 A
2.1 A
4.2 A
2.1 A
10 A
10 A
10 A
www.v-infinity.com
& Noise
100mV
120mV
150mV
100mV
120mV
150mV
100mV
120mV
150mV
Ripple 2
Regulation
Load/Line
±0.5%
±0.3%
±0.2%
±0.5%
±0.3%
±0.2%
±0.5%
±0.3%
±0.2%
1-866-372-1258
Rev. 02/2009
Efficiency
70%
73%
76%
72%
75%
78%
74%
80%
83%
1 / 4

Related parts for VSD-50

VSD-50 Summary of contents

Page 1

... The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 VSD-50 Series Single Output DC-DC Converter Ripple 2 Output Output Voltage Current & ...

Page 2

... AC input needs to be reset to restart the power supply. Over temp. Power supply shuts down when temperature is in excess of 85 ºC. Auto recovery. V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 VSD-50 Series Single Output DC-DC Converter Min Nom 9.2 12 ...

Page 3

... Withstand Voltage I/P-O/P I/P-FG O/P-FG Isolation Resistance I/P-O/P, I/P-FG, O/P-FG Cooling Convection Mechanical Parameter Conditions/Description Weight Enclosure 159(L) x 97(W) x 38(H) mm V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 VSD-50 Series Single Output DC-DC Converter Min Nom -10 -20 20% 10% ±0.3% / ºC (0~50ºC) 10 3000 1500 800 100mΩ min. / 500VDC Min Nom www ...

Page 4

... Assignment Assignment Block Diagram Output Derating V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 VSD-50 Series Single Output DC-DC Converter 152 4 159 6.5 150 22 117 Static Characteristics www.v-infinity.com Rev. 02/2009 1-866-372-1258 ...

Related keywords