RK-0505S-HP RECOM Electronic GmbH, RK-0505S-HP Datasheet

no-image

RK-0505S-HP

Manufacturer Part Number
RK-0505S-HP
Description
Dc/dc-converter
Manufacturer
RECOM Electronic GmbH
Datasheet
34
The RK and RH Series DC/DC-Converter complements Recom’s industrial range of converters with very high
isolations of 3KV and 4kVDC. The extended operating temperature range covering –40°C to +85°C is a
standard feature. The converters are EN-60601-1 certified, making them suitable for medical applications.
Part
Number
SIP 7
RK-xx05S
RK-xx09S
RK-xx12S
RK-xx15S
RH-xx05D
RH-xx09D
RH-xx12D
RH-xx15D
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g.
Input Voltage Range
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
Output Ripple and Noise (20MHz limited)
Operating Frequency
Efficiency at Full Load
No Load Power Consumption
Maximum Capacitive Load
Isolation Voltage
Rated Working Voltage
Isolation Voltage
Rated Working Voltage
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
P-Suffix
Operating Temperature Range (free air convection)
Storage Temperature Range
Relative Humidity
Package Weight
H-Suffix
MTBF (+25°C)
Description
Specifications (
Selection Guide
Features
Unregulated
Converters
Rev.0
(+85°C)
(4kV)
}
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
Detailed Information see
Application Notes chapter "MTBF"
measured at T A = 25°C, nominal input voltage, full load and after warm-up)
H-Suffix
H-Suffix
using MIL-HDBK 217F RH types
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
Voltage
Safety standards and approval:
EN 60950 certified, rated for 250VAC
Optional Continuous Short Circuit Protected
3kVDC & 4kVDC Isolation
Custom Solutions Available
UL94V-0 Package Material
Efficiency to 84 %
(VDC)
Input
1.8V, 3.3V output types
5V output type
9V, 12V, 15V, 24V output types
Single output types
Dual output types
RK types
RH types
RK types
RH types
(tested for 1 second)
(long term isolation)
(tested for 1 second)
(long term isolation)
RK types
RH types
RK types
RH types
RK types
101mW min. / 126mW typ. / 238mW max.
RK-0505S/P, RK-0505S/HP
87mW min. / 130mW typ. / 228mW max.
Voltage
Output
50kHz min. / 100kHz typ. / 105kHz max.
57kHz min. / 100kHz typ. / 105kHz max.
(VDC)
±12
±15
±5
±9
12
15
5
9
-40°C to +85°C (see Graph)
Current
Output
±100
2008
(mA)
±56
±42
±33
200
111
20pF min. / 75pF max.
20pF min. / 65pF max.
84
66
see Application Notes
see Application Notes
70% min. / 80% typ.
1.2%/1% of Vin typ.
-55°C to +125°C
1012 x 10
±75mVp-p max.
100mVp-p max.
992 x 10
145 x 10
151 x 10
3000VDC min.
4000VDC min.
33µF / ±10µF
15 GΩ min.
Continuous
20% max.
15% max.
10% max.
Efficiency
1 Second
95% RH
70-78
70-80
78-82
80-82
74-78
76-79
78-84
80-84
3
3
3
3
±10%
(%)
hours
hours
hours
hours
±5%
2.6g
2.8g
ECONOLINE
DC/DC-Converter
RK
Series
1 Watt
SIP7
Single
Output
EN-60950-1 Certified
EN-60601-1 Certified
Derating-Graph
(Ambient Temperature)
www.recom-electronic.com
&
RH
&
Dual

Related parts for RK-0505S-HP

RK-0505S-HP Summary of contents

Page 1

... Efficiency Description The RK and RH Series DC/DC-Converter complements Recom’s industrial range of converters with very high isolations of 3KV and 4kVDC. The extended operating temperature range covering –40°C to +85° standard feature. The converters are EN-60601-1 certified, making them suitable for medical applications. ...

Page 2

... ECONOLINE DC/DC-Converter Typical Characteristics RK-xx05S RK-xx15S www.recom-international.com RK-xx09S RH-xx05D 2008 RK RH & Series RK-xx12S RH-xx09D 35 ...

Page 3

... ECONOLINE DC/DC-Converter Typical Characteristics RH-xx12D Package Style and Pinning (mm) 7 PIN SIP Package 36 RH-xx15D Recommended Footprint Details Recommended Footprint Details 2008 RK RH & Series Pin Connections Pin Connections RK-xxxxS RH-xxxxD Pin # Dual Pin # Single 1 +Vin 1 +Vin 2 –Vin 2 –Vin 5 –Vout 5 –Vout 7 +Vout ...

Related keywords