ADT7467 Analog Devices, Inc., ADT7467 Datasheet - Page 42
ADT7467
Manufacturer Part Number
ADT7467
Description
Dbcool Remote Thermal Monitor And Fan Controller
Manufacturer
Analog Devices, Inc.
Datasheet
1.ADT7467.pdf
(80 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADT7467
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
ADT7467A
Manufacturer:
PHILIPS
Quantity:
5 212
Part Number:
ADT7467AARQZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADT7467ARQ-REEL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADT7467ARQZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADT7467
STEP 3: T
CALIBRATION CHANNELS
T
using automatic fan control mode. The speed at which the fan
runs at T
temperature-channel specific, for example, 25°C for ambient
channel, 30°C for VRM temperature, and 40°C for processor
temperature.
T
can be programmed in 1°C increments. There is a T
associated with each temperature measurement channel:
Remote 1, local, and Remote 2 temperature. Once the T
value is exceeded, the fan turns on and runs at the minimum
PWM duty cycle. The fan turns off once the temperature has
dropped below T
To overcome fan inertia, the fan spins up until two valid TACH
rising edges are counted. See the Fan Start-Up Timeout section
for more details. In some cases, primarily for psychoacoustic
reasons, it is desirable that the fan never switch off below T
When set, Bits <7:5> of the Enhanced Acoustics Register 1
(Reg. 0x62) keep the fans running at the PWM minimum duty
cycle if the temperature falls below T
MIN
MIN
is the temperature at which the fans start to turn on when
is an 8-bit value, either twos complement or Offset 64, that
MIN
MIN
is programmed later. The T
SETTINGS FOR THERMAL
MIN
AMBIENT TEMP
– T
REMOTE 2 =
REMOTE 1 =
VRM TEMP
CPU TEMP
HYST
LOCAL =
100%
0%
.
THERMAL CALIBRATION
THERMAL CALIBRATION
THERMAL CALIBRATION
T
T
T
T
MIN
MIN
MIN
MIN
MIN
.
MIN
values chosen are
T
T
T
RANGE
RANGE
RANGE
100%
100%
100%
Figure 57. Understanding the T
0%
0%
0%
MIN
register
MIN
MUX
MIN
Rev. A | Page 42 of 80
.
PWM
PWM
PWM
MIN
MIN
MIN
T
Reg. 0x67, Remote 1 temperature T
Reg. 0x68, local temperature T
Reg. 0x69, Remote 2 temperature T
Enhance Acoustics Register 1 (Reg. 0x62)
Bit 7 (MIN3) = 0, PWM3 is off (0% PWM duty cycle) when the
temperature is below T
Bit 7 (MIN3) = 1, PWM3 runs at PWM3 minimum duty cycle
when the temperature is below T
Bit 6 (MIN2) = 0, PWM2 is off (0% PWM duty cycle) when the
temperature is below T
Bit 6 (MIN2) = 1, PWM2 runs at PWM2 minimum duty cycle
when the temperature is below T
Bit 5 (MIN1) = 0, PWM1 is off (0% PWM duty cycle) when the
temperature is below T
Bit 5 (MIN1) = 1, PWM1 runs at PWM1 minimum duty cycle
when the temperature is below T
MIN
MIN
ENHANCEMENT)
ENHANCEMENT)
ENHANCEMENT)
TACHOMETER 1
MEASUREMENT
TACHOMETER 2
MEASUREMENT
TACHOMETER 3
MEASUREMENT
Registers
(ACOUSTIC
(ACOUSTIC
(ACOUSTIC
Parameter
CONTROL
CONTROL
CONTROL
RAMP
RAMP
AND 4
RAMP
GENERATOR
GENERATOR
GENERATOR
CONFIG
CONFIG
CONFIG
PWM
PWM
PWM
PWM
PWM
PWM
MIN
MIN
MIN
– T
– T
– T
HYST
HYST
HYST
MIN
PWM1
TACH1
PWM2
TACH2
PWM3
TACH3
MIN
MIN
MIN
.
.
.
= 0x9A (90°C)
MIN
MIN
FRONT CHASSIS
REAR CHASSIS
– T
– T
– T
CPU FAN SINK
= 0x9A (90°C)
= 0x9A (90°C)
HYST
HYST
HYST
.
.
.