FLA-120 Omron Corporation, FLA-120 Datasheet

no-image

FLA-120

Manufacturer Part Number
FLA-120
Description
General Purpose Relay
Manufacturer
Omron Corporation
Datasheet
• Ideally suited for high-inrush fluid pump controls: pool/spa,
• High-capacity, high-withstand voltage relay with no contact
• UL Class B construction standard.
• Wide-range AC-activated coil that handles 100 to 120 VAC
• Miniature hinge for maximum switching capacity, particular-
• Flame resistant materials (UL94V-0-qualifying) used for
• Quick-connect, screw, and PCB terminals available.
• Standard models are UL, CSA, and TUV approved;
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G7L-1A-T-CB-AC100/120).
Note: 1. E bracket or socket must be used for mounting (part number R99-07G5D). Refer to “Accessories” section for options and part numbers.
E bracket
E bracket
(with test button)
Upper bracket
Upper bracket
(with test button)
PCB mounting
water processing, emergency, chemical industry, etc.
chattering for momentary voltage drops up to 50% of rated
voltage.
at either 50 or 60 Hz.
ly for inductive loads.
all insulation material.
VDE/IEC 950 versions are now available. Meet pollution
degree 3, Material Group II & III.
General Purpose Relay
G7L
2. For VDE approved versions, please consult OMRON.
Type
SPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
DPST-NO
Contact form
G7L-1A-T-CB
G7L-2A-T-CB
G7L-1A-TJ-CB
G7L-2A-TJ-CB
G7L-1A-TUB-CB
G7L-2A-TUB-CB
G7L-1A-TUBJ-CB
G7L-2A-TUBJ-CB
Quick-connect terminal
(see note 1)
(see note 1)
(see note 1)
(see note 1)
G7L-1A-B-CB
G7L-2A-B-CB
G7L-1A-BJ-CB
G7L-2A-BJ-CB
G7L-1A-BUB-CB
G7L-2A-BUB-CB
G7L-1A-BUBJ-CB
G7L-2A-BUBJ-CB
General Purpose Relay
Screw terminal
Model
(see note 1)
(see note 1)
(see note 1)
(see note 1)
G7L-1A-P-CB
G7L-2A-P-CB
G7L
PCB terminal
1

Related parts for FLA-120

FLA-120 Summary of contents

Page 1

... Wide-range AC-activated coil that handles 100 to 120 VAC at either Hz. • Miniature hinge for maximum switching capacity, particular- ly for inductive loads. • Flame resistant materials (UL94V-0-qualifying) used for all insulation material. • Quick-connect, screw, and PCB terminals available. • Standard models are UL, CSA, and TUV approved; ...

Page 2

Model Number Legend G7L- ❏ ❏ - ❏ ❏ ❏ ❏ Contact form 1A:SPST-NO 2A:DPST-NO 2. Terminal shape T:Quick-connect terminals P:PCB terminals B:Screw terminals ■ Accessories Quick-connect Terminals Description E-brackets G7L-1A-T Track ...

Page 3

Coil Data AC Rated voltage Rated current (V) (mA) 6 283 18.90 12 142 303 50 34 1,310 100/120 17.00/20.40 5,260 200/240 8.50/10.20 21,000 DC Rated voltage Rated current (V) (mA) 6 317 18.90 12 158 ...

Page 4

Characteristic Data Maximum switching capacity Switching voltage (V) Dimensions Unit: mm (inch) ■ Relays G7L-1A-T (E Bracket Attached)* G7L-2A-T (E Bracket Attached bracket must be ordered separately. 4 General Purpose Relay Electrical service life Terminal arrangement/ Internal ...

Page 5

G7L-1A-TJ (E Bracket Attached)* G7L-2A-TJ (E Bracket Attached)* G7L-1A-TUB G7L-2A-TUB *E bracket must be ordered separately. Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) ...

Page 6

Unit: mm (inch) G7L-1A-TUBJ G7L-2A-TUBJ G7L-1A-B (E bracket Attached)* G7L-2A-B (E bracket Attached bracket must be ordered separately. 6 General Purpose Relay Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections ...

Page 7

G7L-1A-BJ (E bracket Attached)* G7L-2A-BJ (E bracket Attached)* G7L-1A-BUB G7L-2A-BUB * E bracket must be ordered separately. Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top ...

Page 8

Unit: mm (inch) G7L-1A-BUBJ G7L-2A-BUBJ G7L-1A-P G7L-2A-P 8 General Purpose Relay Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) G7L Mounting holes (Bottom view) ...

Page 9

Accessories E bracket R99-07G5D Adaptor P7LF-D Front connecting socket P7LF-06 Note protect against electric shock, use the P7LF-C cover on terminals. 2. P7LF-C cover is supplied with P7LF-06 socket. Mounting holes (Bottom view) Mounting holes (Bottom view) ...

Page 10

Unit: mm (inch) Cover P7LF-C Note: P7LF-C cover is supplied with P7LF-06 socket. Mounting track PFP-100N, PFP-50N Note recommended that a panel thickness of 1.60 to 2.00 mm (0.06 to 0.08 in) be used ...

Page 11

... A, 277 VAC, General Use, 100,000 c 1.5 kW, 120 VAC, Tungsten 1.5 HP, 120 VAC 3 HP, 240/265/277 VAC, 100,000 c 20 FLA/120 LRA, 120 VAC, 30,000 c Screw 17 FLA/102 LRA, 277 VAC, 30,000 c TV-10, 120 VAC 20 A (2.4 kW), 120 VAC, Tungsten 20 A, (4.8 kW), 240 VAC, Tungsten 6,000 PCB 20 A, 277 VAC, Ballast 10,000 c ...

Page 12

... The tape should then be removed after processing. ■ Applications • Compressors for package air conditioners and heater switching controllers • Switching controllers for power tools or motors • Power controllers for water heaters • Power controllers for dryers • Lamp control, motor drivers, and power supply switching in copy machines, facsimiles, and other OA equipment • ...

Page 13

Omron Electronic Components, LLC Terms and Conditions of Sales I. GENERAL 1. Definitions: The words used herein are defined as follows. (a) Terms: These terms and conditions (b) Seller: Omron Electronic Components LLC and its subsidiaries (c) Buyer: The buyer ...

Page 14

Certain Precautions on Specifications and Use 1. Suitability for Use. Seller shall not be responsible for conformity with any stan- dards, codes or regulations which apply to the combination of the Product in Buyer's application or use of the Product. ...