ZY2160 Power-One, ZY2160 Datasheet

no-image

ZY2160

Manufacturer Part Number
ZY2160
Description
Zy2160 60a No-bus Pol
Manufacturer
Power-One
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ZY2160G
Manufacturer:
RENESAS
Quantity:
3 000
Part Number:
ZY2160G
Manufacturer:
POWER-ONE
Quantity:
20 000
Applications
Benefits
Description
The ZY2160 is an intelligent, fully programmable step-down point-of-load DC-DC module integrating digital power
conversion and power management. The ZY2160 completely eliminates the need for external components for
sequencing, tracking, protection, monitoring, and reporting.
programmable by pin strapping and an external resistor and can be changed by the user at any time during
product development and service without a need for a communication bus.
Reference Documents
No-Bus
Z-One
Z-One
ZD-01966 REV. 1.0
Low voltage, high density systems with
Intermediate Bus Architectures (IBA)
Point-of-load regulators for high performance DSP,
FPGA, ASIC, and microprocessor applications
Industrial computing, servers, and storage
Broadband, networking, optical, and wireless
communications systems
Active memory bus terminators
Integrates digital power conversion with intelligent
power management
Eliminates the need for external power
management components and communication bus
Completely programmable via pin strapping and
one external resistor
One part that covers all applications
Reduces board space, system cost and
complexity, and time to market
®
®
TM
POL Converters. Eutectic Solder Process Application Note
POL Converters. Lead-Free Process Application Note
POL Converters. Application Note
www.power-one.com
Features
8V to 14V Input
ZY2160 60A No-Bus POL Data Sheet
RoHS lead free and lead-solder-exempt products are
available
Wide input voltage range: 8V–14V
High continuous output current: 60A
Wide programmable output voltage range: 0.5V–
2.75V
Active digital current share
Output voltage margining
Overcurrent and overtemperature protections
Overvoltage and undervoltage protections, and Power
Good signal tracking the output voltage setpoint
Tracking during turn-on and turn-off with guaranteed
slew rates
Sequenced and cascaded modes of operation
Single-wire line for frequency synchronization
between multiple POLs
Programmable feedback loop compensation
Differential output voltage sense
Enable control
Flexible fault management and propagation
Start-up into the load pre-biased up to 100%
Current sink capability
Real time current measurements, monitoring, and
reporting
Industry standard size through-hole single-in-line
package: 2.4”x0.55”
Low height of 1.1”
Wide operating temperature range: 0 to 70ºC
UL60950 recognized, CSA C22.2 No. 60950-00
certified, and TUV EN60950-1:2001 certified
Member of the
Performance parameters of the ZY2160 are
0.5V to 2.75V Output
Page 1 of 14
Family

Related parts for ZY2160

ZY2160 Summary of contents

Page 1

... Reduces board space, system cost and complexity, and time to market Description The ZY2160 is an intelligent, fully programmable step-down point-of-load DC-DC module integrating digital power conversion and power management. The ZY2160 completely eliminates the need for external components for sequencing, tracking, protection, monitoring, and reporting. ...

Page 2

... Mercury (Hg), Polybrominated biphenyls (PBB), Polybrominated diphenylethers (PBDE), and Lead (Pb) used anywhere except in solder. 2 Packaging option is used only for ordering and not included in the part number printed on the POL converter label. Example: ZY2160G-R3: A 30-piece tray of RoHS compliant POL converters. Each POL converter is labeled ZY2160G. 2. Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long- term reliability, and cause permanent damage to the POL converter ...

Page 3

... At the negative output current (bus terminator mode) efficiency of the ZY2160 degrades resulting in increased internal power dissipation. Maximum allowable negative current is limited to 40A. 2 ZY2160 is a step-down converter, thus the output voltage is always lower than the input voltage as show in Error! Reference source not found.. 3 Digital PWM has an inherent quantization uncertainty of ± ...

Page 4

... Follows the output voltage setpoint From instant when threshold is exceeded until Delay Threshold Accuracy ___________________ 1 Minimum OVP threshold is 1.0V ZD-01966 REV. 1.0 ZY2160 60A No-Bus POL Data Sheet 8V to 14V Input Conditions/Description Output Overcurrent Protection Output Overvoltage Protection Measured at V =2.5V O.SET Output Undervoltage Protection Measured ...

Page 5

... Recommended C Output Current Monitoring Accuracy Conversion Ratio corresponding to 100% of nominal current Type Voltage Drop Compensation Voltage Drop Compensation ZD-01966 REV. 1.0 ZY2160 60A No-Bus POL Data Sheet 8V to 14V Input Conditions/Description Current Share (CS pin) I ≥20%*I OUT MIN OUT NOM Tracking Proportional to SYNC frequency ...

Page 6

... ViH_CS Vhyst_CS Hysteresis of input Schmitt trigger IoL_CS LOW level sink current V(CS)=0.5V Tr_CS Maximum allowed rise time 10/90% VDD ZD-01966 REV. 1.0 ZY2160 60A No-Bus POL Data Sheet 8V to 14V Input Conditions/Description Internal supply voltage 3.15 SYNC Line LOW level input voltage 0.75 x HIGH level input voltage VDD 0 ...

Page 7

... Figure 1. Output Voltage as a Function of Input Voltage 5.1 Efficiency Curves Vo=0.75V Vo=1.0V Vo=1.8V Vo=2. Output Current, A Figure 2. Efficiency vs. Load. Vin=9.6V ZD-01966 REV. 1.0 ZY2160 60A No-Bus POL Data Sheet 8V to 14V Input Vo=1. Figure 3. Efficiency vs. Load. Vin=12V www.power-one.com 0.5V to 2.75V Output • Vo=0.75V Vo=1.0V Vo=1.2V Vo=1 ...

Page 8

... Vo=0.5V Vo=1. Input Voltage, V Figure 5. Efficiency vs. Input Voltage. Iout=60A ZD-01966 REV. 1.0 ZY2160 60A No-Bus POL Data Sheet 8V to 14V Input 5.2 Turn-On Characteristics Vin=12V 2 2.5 Figure 6. Tracking Turn-On. Vin=12V, Ch1 – V1, Ch2 – V2, Ch3 – V3 Vo=2.5V 5.3 Turn-Off Characteristics 13 14 Figure 7. Tracking Turn-Off Vin=12V, Ch1 – ...

Page 9

... LFM 100 LFM (0.5 m/s) 30 200 LFM (1 m/s) 300 LFM (1.5 m/s) 400 LFM (2 m/s) 500 LFM (2.5 m/ Figure 10. Thermal Derating Curves. Vin=12V, Vout=2.5V ZD-01966 REV. 1.0 ZY2160 60A No-Bus POL Data Sheet 8V to 14V Input Figure 9. Vin=12V, Vout=2.5V. CCA Ambient Temperature, C www.power-one.com 0.5V to 2.75V Output • ...

Page 10

... POL1 is configured as a master (IM pin is grounded) and all other POL converters are synchronized to the switching frequency of POL1. All converters are controlled by the common ENABLE signal. Turn-on and turn-off processes of the system are illustrated by pictures in Figure 6 and Figure 7. ZD-01966 REV. 1.0 ZY2160 60A No-Bus POL Data Sheet 8V to 14V Input OK VIN VIN 22uF 22uF 4 ...

Page 11

... P 19, 21, 23 VIN 12 Legend: I=input, O=output, I/O=input/output, P=power, A=analog, PU=internal pull-up ZD-01966 REV. 1.0 ZY2160 60A No-Bus POL Data Sheet 8V to 14V Input Pin Description Connect to OK pin of other Z- POLs. Leave Fault Status Frequency Synchronization Connect to SYNC pin of other Z-POLs ...

Page 12

... POL input protected by a fast- acting 32V, 25A, fuse fuse rated greater than 25A is used, additional testing may be required. In order for the output of the ZY2160 POL converter to be considered as SELV (Safety Extra Low Voltage), according to ...

Page 13

... R DOWN TRIM − 100 ⎝ ZD-01966 REV. 1.0 ZY2160 60A No-Bus POL Data Sheet 8V to 14V Input where R TRIM ∆V% is the absolute value of desired margining expressed in percents of the nominal output voltage. During normal operation the resistors are removed from the circuit by the switches. ...

Page 14

... Power-One, Inc. 2. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. ZD-01966 REV. 1.0 ZY2160 60A No-Bus POL Data Sheet 8V to 14V Input All Dimensions are in mm XX.X: ±0.1 XX.XX: ± ...