MKP1839HQ Vishay, MKP1839HQ Datasheet - Page 9

no-image

MKP1839HQ

Manufacturer Part Number
MKP1839HQ
Description
Ac And Pulse Metallized Polypropylene Film Capacitors Mkp Axial Type
Manufacturer
Vishay
Datasheet
MKP 1839 HQ
Vishay Roederstein
Voltage Conditions for 6 Above
INSPECTION REQUIREMENTS
General Notes:
Sub-clause numbers of tests and performance requirements refer to the “Sectional Specification, Publication IEC 60384-17 and
Specific Reference Data”.
Group C Inspection Requirements
www.vishay.com
266
ALLOWED VOLTAGES
Maximum continuous RMS voltage
Maximum temporary RMS-overvoltage (< 24 h)
Maximum peak voltage (V
SUB-CLAUSE NUMBER AND TEST
SUB-GROUP C1A PART OF SAMPLE
OF SUB-GROUP C1
4.1
4.3.1
4.3
4.4
4.4.2
4.14
SUB-GROUP C1B PART OF SAMPLE
OF SUB-GROUP C1
4.6.1
4.6
Dimensions (detail)
Initial measurements
Robustness of terminations
Resistance to soldering heat
Final measurements
Solvent resistance of the marking
Initial measurements
Rapid change of temperature
O-P
) (< 2 s)
AC and Pulse Metallized Polypropylene Film Capacitors
For technical questions, contact: dc-film@vishay.com
Capacitance
Tangent of loss angle at 100 kHz
Tensile: Load 30 N; 10 s
Bending: Load 15 N; 90°
No pre-drying
Method: 1A
Visual examination
Capacitance
Tangent of loss angle
Insulation resistance
Isopropylalcohol at room temperature
Method: 1
Capacitance
Tangent of loss angle at 100 kHz
θA = - 55 °C
θB = + 110 °C
5 cycles
Duration t = 30 min
Visual examination
Solder bath: 280 °C ± 5 °C
Duration: 10 s
Rubbing material: Cotton wool
Immersion time: 5 ± 0.5 min
CONDITIONS
MKP Axial Type
T
1.25 x U
amb
1.6 x U
U
≤ 85 °C
Rac
Rdc
Rac
As specified in chapter “General Data” of this
specification
No visible damage
No visible damage
Legible marking
|ΔC/C| ≤ 2 % of the value measured initially
Increase of tan δ:
Compared to values measured initially
≥ 50 % of values specified in section
“Insulation Resistance” of this specification
No visible damage
Legible marking
No visible damage
For C ≤ 470 nF ≤ 0.001 (10 x 10
For C > 470 nF ≤ 0.0015 (15 x 10
PERFORMANCE REQUIREMENTS
See “Maximum AC voltage as a
function of temperature par.
85 °C < T
characteristics”
Document Number: 28162
0.875 x U
1.1 x U
amb
Revision: 16-Jan-09
Rdc
≤ 110 °C
Rac
-4
-4
)
)

Related parts for MKP1839HQ