CMCG24S2.5-6000 Wall Industries,Inc., CMCG24S2.5-6000 Datasheet - Page 5

no-image

CMCG24S2.5-6000

Manufacturer Part Number
CMCG24S2.5-6000
Description
30 Watt Single Output 2 1 Input Voltage Range Chassis Mount Dc/dc Converter
Manufacturer
Wall Industries,Inc.
Datasheet
CMCG Series
30 Watt Single Output
Rev. B
2:1 Input Voltage Range
Chassis Mount DC/DC Converter
Over Current Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current
limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit
operates normally once the output current is brought back into its specified range.
Output Over Voltage Protection
The output over voltage clamp consists of control circuitry, which is independent of the primary regulation loop that monitors the voltage on
the output terminals. The control loop of the clamp has a higher voltage set point than the primary loop. This provides a redundant voltage
control that reduces the risk of output over voltage. The OVP level can be found in the “Output Voltage / Current Rating Chart.”
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module, and board spacing. To
avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below
.
105°C. The derating curves are determined from measurements obtained in an experimental apparatus
Efficiency vs Input Voltage
Efficiency vs Output Load
DERATING CURVE
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797