EM65570 ELAN Microelectronics Corp, EM65570 Datasheet - Page 26

no-image

EM65570

Manufacturer Part Number
EM65570
Description
68com / 98seg 65k Color Stn Lcd Driver
Manufacturer
ELAN Microelectronics Corp
Datasheet
EM65570
68COM/ 98SEG 65K Color STN LCD Driver
20 x
7.4 16-Bit Data Access to Display RAM
7.3.2 Register Read Operation
The EM65570 can read the control registers. When issuing a control register read
operation, the upper data bus nibble (D7-D4) is used for the register address (0 to FH).
Up to 16 registers can be accessed directly. However, more than 16 registers are
provided. To solve this over supply problem, the EM65570 uses the register bank
control to access the RE register with a bank number. You can access the RE register
through any bank. The following lists the steps to be taken when accessing the specific
register using the bank access control.
1. Set 01H to RE register for access to the RA register.
2. Set the specific register address to the RA register.
3. Set the specific register bank to the RE register.
4. Read the contents at the specific register.
selected by the WLS register.
„ WLS = “0”: 8-bits bus size
„ WLS = “1”: 16-bits bus size
(D7~D0) in the internal circuit and does not use the high-byte data bus (D15~D8).
When reading control register using 16-bit bus, data exist at D3~D0 while D15~D4 is
always 1 or “H”.
The EM65570 has both 8-bit and 16-bit data bus sizes. The data bus size can be
In 16-bit access mode, the Control Register Access uses the low-byte data bus
D0~D7
WRB
RDB
RS
Bank number write
Figure 7-6 Register Read Operation
to RE for RA
01H
(This specification is subject to change without further notice)
Address write
addr
to RA
Product Specification (V1.0) 09.05.2005
Bank number
write to RE
bank
read specific
register
data