Description
3 1/2 Digit, Lcd Display Low-cost, Subminiature Digital Panel Voltmeters
Manufacturer
ETC-unknow
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DMS-20LCD-1-9-C
Manufacturer:
Murata Power Solutions Inc
Quantity:
135
Part Number:
DMS-20LCD-1-DCM-C
Manufacturer:
Murata Power Solutions Inc
Quantity:
135
Part Number:
DMS-20LCD-3-5B-C
Manufacturer:
MURATA/村田
Quantity:
20 000
6. Power Supply Monitoring: A popular application for DATEL's
function of the scaling requirements of the particular application and
can be calculated using the following equation:
Where:
Example: For a meter with a 2V full scale input (1.999 full
scale reading) and a desired full scale display reading of
1000 (with an input of 20mA), V
To calibrate the circuit of Figure 7, perform the following:
1. With 4mA applied, adjust the 50k potentiometer (R2) to
2. With 20mA applied, adjust the gain-adjust potentiometer on
low-power LCD meters is monitoring the supply voltage in battery-
operated portable equipment. Figure 8 demonstrates how a 9V-
powered DMS-20LCD can be used to monitor its own supply. The
meter used is the DMS-20LCD-1-9. A three-resistor voltage
divider is used to attenuate the battery voltage and also to satisfy
the requirement that the input voltages applied to pins 12 and 11
be at least 1.5 Volts above and below the battery voltage applied
to pins 1 (+BATTERY) and 3 (–BATTERY). The divider should be
designed so that 1/10th the battery voltage falls across the inputs
to the meter:
display a reading of "000" (assuming that is the desired
reading).
the back of the meter to display a reading of "1999". For different
full scale readings, alter the value of R
4 - 2 0 m A
8 5 - 2 6 4 V a c
+
R
R
R
3 ½ D I G I T , L C D D I S P L A Y D I G I T A L P A N E L V O L T M E T E R S
Shunt
V
Shunt
Shunt
Figure 7. 4-to-20mA Current Loop Operation
I
Fsr
Fsr
A C t o D C C o n v e r t e r
R 1
D M S - P S 1 - C M
= R1 = V
= Full scale reading (in Volts)
= Relative full scale current (in Amps)
= 1.000V/(0.020 – 0.004)A
= 1.000V/0.016A = 62.5 Ohms
D A T E L
A N A C O M M
5 0 k
( – ) I N L O
(5V-Powered Models)
( + ) I N H I
R 2
Fsr
1 1
1 0
1 2
/ I
Fsr
+ 5 V S U P
D M S - 2 0 L C D - 1 - 5
Fsr
1
= 1.000 Volts
Shunt
5 V R E T
3
accordingly.
R E F I N
8
R E F O U T
7
Applications
5
7. External Gain Adjustment: Connect REFERENCE OUT
12
For +5V models, tie (–) IN LO to pin 3.
For +9V models, tie (–) IN LO to pin 10
Therefore, the 9V battery voltage appears to the meter inputs
as 0.9V. With the decimal point moved to its DP2 position
(pin 5 tied to pin 3), the meter reads 9.00 Volts.
The circuit can be calibrated by first measuring the actual
battery voltage with another meter and then adjusting the gain-
adjust potentiometer on the back of the DMS-20LCD until a
similar reading is obtained. If possible, the resistors in the
divider should be ±1% metal-film types with TCR's less than
50ppm/°C.
(pin 8) to REFERENCE IN (pin 7) for normal, factory calibrated,
operation. Use the circuit shown in Figure 9 for applications
needing external gain adjustment. Calibration is performed with
a precise, near-full-scale, input voltage.
CALIBRATOR
VOLTAGE
OUT
COM
REF OUT
REF IN
(R1 + R2 + R3)
BATTERY
9V
Figure 9. External Gain Adjustment
7
8
Figure 8. Power Supply Monitor
+BAT
(–) IN LO
(+) IN HI
5V RET/
–BAT IN
R2
1
(9V-Powered Models)
11
12
COMM
DMS-20LCD-1-9
3
ANA
10
732, 1%
8.06k, 1%
= 0.1
–BAT
3
NC
DMS-20LCD
8
Q
= 10 to 20 Turns
REF
DP2
5
IN
7
200
(+) IN HI
(–) IN LO
11
12
2k
Q
Q
+BAT IN
17.4k, 1%
+5V IN/
24.3k, 1%
1
DMS-20LCD
45.3k
10.1k
45.3k
R1
R2
R3
and ±200V models
Connections
for ±200mV
for ±2V, ±20V
models
Connections

Related parts for DMS-20LCD