BFD3.3SX ETA-USA, BFD3.3SX Datasheet

no-image

BFD3.3SX

Manufacturer Part Number
BFD3.3SX
Description
Ac-dc Converter Power Supply
Manufacturer
ETA-USA
Datasheet
Application
Industrial
Input
Input Voltage:
Input Voltage Range:
Input Current:
Frequency:
Input Frequency Range:
Phase:
Inrush Current: *1
Leakage Current:
Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037
ETA USA
AC100-240V
AC85-264V
2.0-0.9 A
50/60Hz
47-63Hz
Single
18A(typ.) at AC100V
41A(typ.) at AC230V
1mA(maximum)at 25
(
rated input frequency)
rated input/output and
BFD-SX-U1
SERIES
°C
General Description
“BF”-Series AC/DC Switching power supplies are board
type power supplies matched with new designs, which is
in accordance with harmonic current regulation, of
ultra-small sizes, high efficiency and low cost. By
adopting the synchronization regular method (output less
than 6 V) for the first time for this class of devices,
BF-Series is 40mm smaller in depth compared with
equivalent products by other makers. At the same time
low cost is realized to meet market needs.
Features
Options
1.
2.
3.
4.
5.
6.
7.
8.
9.
N/A
Visit us at: www.eta-usa.com
Board Type
Ultra Small size
Universal input(AC 85V to 264V)
Harmonic current complies to IEC61000-3-2
Power factor BFD: 0.98/0.92 (AC 100/230V)
High efficiency
Low Cost
EMI: complies to FCC class B, or EN55022
class B, or VCCI class B
Safety: UL 60950-1 2
EN 60950-1 2006
email at: sales@eta-usa.com
A
A
C
C
/
/
D
D
S
S
C
C
I
I
N
N
S
S
G
G
W
W
A
A
L
L
I
I
C
C
nd
T
E
T
E
C
C
I
edition, C-UL,
I
1
1
C
C
N
N
H
H
0
0
H
H
P
P
I
0
0
I
N
N
A
U
A
U
W
W
G
G
N
T
N
T
A
A
N
N
P
P
8
8
T
T
O
E
E
O
5
5
T
T
~
~
L
L
W
W
S
S
2
2
O
O
E
E
6
6
R
4
U
R
4
U
V
V
T
T
S
S
P
P
U
U
U
U
P
P
T
T
P
P
L
L
Y
Y

Related parts for BFD3.3SX

BFD3.3SX Summary of contents

Page 1

... Harmonic current complies to IEC61000-3-2 5. Power factor BFD: 0.98/0.92 (AC 100/230V) 6. High efficiency 7. Low Cost 8. EMI: complies to FCC class B, or EN55022 class B, or VCCI class B 9. Safety: UL 60950 60950-1 2006 °C Options N/A Visit us at: www.eta-usa.com email at: sales@eta-usa.com ...

Page 2

... Output Characteristic Unit BFD3.3SX Output Voltage Vdc 3.3 Output Current A 20 Voltage Adjust Range V Ripple&Noise(max)*2 mVpp 120/160 Rise up time mS Hold up time mS Regulation a. Line Regulation mV 9.9 b. Load Regulation * Temperature °C Coefficient *4 d. Drift(maximum 13.2 e. Dynamic Load 0.2 mV Regulation (typ Recovery Time *6 ...

Page 3

... Current Limiting with automatic recovery output shutdown(to reset,leave 1minute after shut-off) not available not available not available available not available 62W × 180L × 35H 320g Visit us at: www.eta-usa.com email at: sales@eta-usa.com 50MΩ(minimum) by DC500V 2 ,20minutes' edition nd C-UL: CSA C22.2 398000 ...

Page 4

... ETA USA 16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753 ( Visit us at: www.eta-usa.com email at: sales@eta-usa.com ...

Page 5

... EFFICIENCY CURVE ETA USA 16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753 DERATING CURVE Visit us at: www.eta-usa.com email at: sales@eta-usa.com OCP CURVE ...

Related keywords