Input Voltage
Brown Out
No Load Power Dissipation
Inrush Charge
Reflective Ripple Current
Logic Disable Current (Sink)
Logic Disable Power In
Input Ripple Rejection (120 Hz)
Input Ripple Rejection (800 Hz)
Efficiency (FL)
EMI:
Input Transient:
1111 Knox Street
Series
Total Output Power
Single (S), Dual (D) Output
Industrial (I) or Military (M)
How to Order:
N H 1 0 0 D I / 5 / 1 5 - A - D
INPUT CHARACTERISTICS
INPUT CHARACTERISTICS
S
Units conform to MIL-STD-461D (on the input leads) with companion filter
100 Watts Output Power
S
NH100
TABILITY
INGLE
0 dB
(75% of Full Load) (fig. I)*
3.3 Vdc Output (FL)
2 Vdc Output (FL)
(fig. VII)*
(fig. II, III)*
Phase
Gain
Units conform to MIL-STD-704D for transients up to 500V for 0.1 second
& D
UAL OUTPUTS
(fig. VIII)*
- - - -
-------
Torrance
Min.
200
180
75
70
60
Output Voltage:
Maximum current
as stated in chart
P
Typ.
0.24
270
200
ER
10
75
60
80
74
65
4
4
C
CA 90502
HANNEL
Options:
A- pins out side of unit
B- pins out bottom of unit
C- pins out top of unit
D- through hole inserts
I - M2.5 inserts
-180°
(STD threaded)
180°
Max.
400
0.4
6
5
0°
Units
Watt
Vdc
Vdc
mA
mA
mc
dB
dB
W
%
%
%
USA
•
•
•
•
•
•
•
•
•
•
•
✝
* Figures on page 10
** Features referenced to Output Ground
*** Features referenced to Channel 1 Output Ground
Set Point Accuracy
Load Regulation
Line Regulation
Ripple P-P (10 MHz)
100mV or 1% Vout, whichever is greater
Trim Range
Remote Sense Compensation
Overvoltage Protection
Current Sharing
Transient Response
Temperature Drift
Long Term Drift
Current Limit
Short Circuit Current
Turn On Time
Logic Turn On Time
SELECTION CHART
OUTPUT CHARACTERISTICS
SELECTION CHART
OUTPUT CHARACTERISTICS
1% or 50mV, whichever is greater
FEA
FEA
Tel: +1 310 202 8820
Nominal
Voltage
Output
TURES
TURES
3.3
5.2
.38 Inch Profile
Power Good***
Synchronization**
Remote Turn On (TTL)***
Output Voltage Trim Pin**
Single and Dual Outputs
Over Temperature Protection
N+1 Redundancy (Single Output)
Output Overvoltage/Overcurrent Protection
100% Environmental Screening (Military Version)
Outputs Isolated Allowing Any Combination of
Output Voltages
12
15
24
28
2
5
20-80% Load
Low Line - High Line
50-100% Load
(fig. XI)*
(fig. IX)*
(Recovery to 1%Vout
(fig. IV)*
(Burp Mode)
Min.
Current
25
Output
(Amps)
Single
19.2
8.4
6.7
4.2
3.6
20
20
20
) Time/Overshoot
sales@martekpower.com
500/500
500/500
500/500
Typ.
±10
125
±10
130
P
0.5
.05
.05
1.0
60
ER
C
HANNEL
Per Channel
Max.
100
1
0.5
0.5
Current
75
(Amps)
Dual
✝
9.6
4.2
3.3
2.1
1.8
10
10
10
%/1KHrs
μS/mV
μS/mV
μS/mV
% V
% V
% V
% V
% V
Units
%/°C
% I
% I
% I
Vdc
mV
mS
mS
out
out
out
out
out
out
out
out
>> 4