LCP-155B4JDRAX-0B Delta Electronics, Inc., LCP-155B4JDRAX-0B Datasheet
LCP-155B4JDRAX-0B
Related parts for LCP-155B4JDRAX-0B
LCP-155B4JDRAX-0B Summary of contents
Page 1
... Duplex LC connector interface Applications SONET OC-3/SDH STM-1 ATM Network for high-speed Fast Ethernet Switch to Switch interface Switched backplane applications File server interface Agreement Performance LCP-155B4JDRAx Data Link up to 15km in 9/125μm Single Mode Fiber digital diagnostic , Nov., 2006 Rev. 0B www.deltaww.com ...
Page 2
... Output Data Rise/Fall Time Notes: 1. Internally AC coupled and terminated to 100Ohm differential load. 2. Pull host Board Internally AC coupled, but requires a 100Ohm differential termination at or internal to Serializer/ Deserializer. 4. These are 20%~80% values. DELTA ELECTRONICS, INC. Symbol Min. Typ Symbol Min ...
Page 3
... LOS-Asserted (Avg.) LOS-Hysteresis (Avg.) Overload (Avg.) Notes: 1. These are unfiltered 10%~90% values 2. The sensitivity is provided at a BER of 1× PRBS and ER=9dB. Mask of the eye diagram for the optical transmit signal DELTA ELECTRONICS, INC NRZ) Symbol Min. Typ ...
Page 4
... SFP Transceiver Electrical Pad Layout DELTA ELECTRONICS, INC. 4 www.deltaww.com Nov., 2006 Rev. 0B ...
Page 5
... SERDES. The AC coupling is done inside the module and is thus not required on the host board. The voltage swing on these lines will be between 370 and 2000 mV differential (185 – 1000 mV single ended) when properly terminated. DELTA ELECTRONICS, INC. Function Plug Seq. ...
Page 6
... EMI performance. Recommend Circuit Schematic VCC Protocol Vcc Tx_Disable Tx_Fault Protocol IC SerDes IC Rx_LOS PLD / PAL DELTA ELECTRONICS, INC. 1uH 3.3V 1uH RES1 10uF 0.1uF Tx_Disable Tx_Fault ...
Page 7
... Package Outline Drawing DELTA ELECTRONICS, INC. 7 www.deltaww.com Nov., 2006 Rev. 0B ...
Page 8
... From power on or negation of TX_Fault using TX Disable 3) Time from fault to TX fault on. 4) Time TX Disable must be held high to reset TX_Fault 5) 6) Time from LOS state to Rx LOS assert 7) Time from non-LOS state to Rx LOS deassert DELTA ELECTRONICS, INC. Symbol Min. t_off t_on t_init t_fault t_rest ...
Page 9
... Vender Specific (32 bytes) 127 128 Reserved in SFP MSA (128 bytes) 255 Digital Diagnostic Memory Map Specific Data Field Descriptions DELTA ELECTRONICS, INC. 2 wire address 1010001 X (A2h) 0 Alarm and Warning Thresholds (56 bytes Cal Constants (40 bytes Real Time Diagnostic Interface ...
Page 10
... Byte 3~10: Code for electronic compatibility or optical compatibility. 2) Byte 14:Transmission distance Byte 15: Transmission distance in 100m, distance >25.5km: FFh 4) Byte 40-55: Delta part number 5) Byte 60-61: The center wavelength of transmitter 6) Byte 63: Check sum of bytes 0-62. 7) Byte 68-83: Serial number. DELTA ELECTRONICS, INC. Address Hex ASCII ...
Page 11
... Optional Set of Alarm and Warning Notes Case Operating temperature Operating current at room temperature. The min. setting current Operating optical power of transmitter at room temperature Overload optical power of receiver 0 DELTA ELECTRONICS, INC. Name Value (Dec.) T (MAX.)+ (MAX.)+ (MIN ...
Page 12
... Parameter Transceiver Temperature Power Supply Voltage TX Bias Current TX Optical Power RX Optical Power Notes: DELTA ELECTRONICS, INC. Name Digital state of the Tx disable input pin Read/ Write bit that allow software disable of laser NA NA Digital state of the Tx fault output pin Digital state of the LOS output pin. ...
Page 13
... Voltage is measured internal to the transceiver Regulatory Compliance Test Item (#1) Electromagnetic Interference EMC (#2) Immunity: Radio Frequency Electromagnetic Field (#3) Immunity: Electrostatic Discharge to the Duplex SC Receptacle (#4) Electrostatic Discharge to the Electrical Pins Ordering information for SFP modules LCP-155X ...