LCP-155B4MDRX-0B Delta Electronics, Inc., LCP-155B4MDRX-0B Datasheet - Page 5

no-image

LCP-155B4MDRX-0B

Manufacturer Part Number
LCP-155B4MDRX-0B
Description
Rohs Compliant Sfp Transceiver For Atm, Sonet Oc-3/sdh Stm-1 With Digital Diagnostic Monitoring Function
Manufacturer
Delta Electronics, Inc.
Datasheet
Pin Function Definitions
Plug Seq.: Pin engagement sequence during hot plugging.
Notes:
1)
2)
3)
4)
5)
6)
DELTA ELECTRONICS, INC.
Pin Num.
10
12
13
14
15
16
17
18
19
20
11
1
2
3
4
5
6
7
8
9
board. Pull up voltage between 2.0V and VccT, R+0.3V. When high, output indicates a laser fault of some kind.
Low indicates normal operation. In the low state, the output will be pulled to < 0.8V.
with a 4.7 – 10 K Ω resistor. Its states are:
host board. The pull-up voltage shall be VccT or VccR (see Section IV for further details). Mod-Def 0 is grounded
by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for
serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID
Pull up voltage between 2.0V and VccT, R+0.3V. When high, this output indicates the received optical power is
below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In
the low state, the output will be pulled to < 0.8V.
terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus
not required on the host board. The voltage swing on these lines will be between 370 and 2000 mV differential
(185 – 1000 mV single ended) when properly terminated.
TX Fault is an open collector/drain output, which should be pulled up with a 4.7K – 10KΩ resistor on the host
TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module
Low (0 – 0.8V):
(>0.8, < 2.0V):
High (2.0 – 3.465V):
Open:
Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K – 10KΩresistor on the
LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K – 10KΩ resistor.
VeeR and VeeT may be internally connected within the SFP module.
RD-/+: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be
MOD-DEF2
MOD-DEF1
MOD-DEF0
Rate Select
TX Disable
TX Fault
Name
VeeR
VeeR
VeeR
VeeR
VeeT
VccR
VccT
VeeT
VeeT
LOS
RD+
TD+
RD-
TD-
Module Definition 2
Module Definition 1
Module Definition 0
Not Connect
Transmitter Ground
Transmitter Fault Indication
Transmitter Disable
Loss of Signal
Receiver Ground
Receiver Ground
Receiver Ground
Inv. Received Data Out
Received Data Out
Receiver Ground
Receiver Power
Transmitter Power
Transmitter Ground
Transmit Data In
Inv. Transmit Data In
Transmitter Ground
Transmitter on
Undefined
Transmitter Disabled
Transmitter Disabled
Function
5
Plug Seq.
3
1
3
3
3
3
3
3
3
1
1
1
3
1
2
2
1
3
3
1
Note 2
Module disables on high or open
Note 3, Grounded in Module
Function not available
Note 5
Note 5
Note 5
Note 7
Note 5
3.3 ± 5%, Note 7
Note 5
Note 8
Note 8
Note 5
Note 1
Note 3, 2 wire serial ID interface
Note 3, 2 wire serial ID interface
Note 4
Note 6
3.3 ± 5%, Note 7
www.deltaww.com
Notes
2008/1/31
Rev. 0B

Related parts for LCP-155B4MDRX-0B