F e a t u r e s a n d B e n e f i t s
S p e c i f i c a t i o n s
Feature
ITEMS
Input Voltage range
Input Frequency
Inrush Current
Power Factor Harmonics
Voltage Setting
Total Regulation
Ripple & Noise
Efficiency
Overcurrent Protection
Overvoltage Protection
Overtemperature Protection
Hold Up Time (Typ)
Leakage Current (max)
Fan Supply
Standby Voltage
Remote Sense
Signals & Features
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Isolation
Vibration (non operating)
Shock
Safety Agency Approvals
Immunity
Conducted Emissions and Flicker
Radiated Emissions
Weight (open frame or enclosed)
Size (Open frame style)
Warranty
(1) Including underside component leads
Full Digital Control
High Efficiency
Low Profile
Reinforced Isolation (4kVAC input to output)
(2)
(4)
(1)
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
mV
EFE300M & 400M
ms
µA
yrs
in
A
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Remote on/off - Inhibit or Enable operation (chosen at time of ordering) Power Good - High
123µA 120VAC 60Hz, 257µA 240VAC 60Hz, <300µA 264VAC 63Hz (Type Test results)
IEC/UL/EN/CSA22.2 60601-1, IEC/EN 61010-1, IEC/UL/EN/CSA22.2 No 60950-1, CE for LVD
Setting: -5% to +10% (Chosen at time of ordering), Accuracy: +/-1% at 50% Load
2G, 10-500Hz (sweep & endurance at resonance) in all 3 planes. MIL-STD-810E,
Input to Ground 2.3kVDC, Input to Output 4kVAC, Output to Ground 1500VAC
indicates supply is good. ORing FET - Allows redundant connection of supplies
30G per IEC68-2-27, MIL-STD-810E/F, Method 516.5, Pro I, IV, VI
< 4% with 90 - 264VAC input change and 0-100% load change
EN55011, EN55022 Class B (per CISPR.11/22), EN61000-3-3
Forced air, 2m/s from input to output (approximately 10CFM)
405g or 635g
0 to +70°C. Derate linearly to 50% load from 50°C to 70°C
3 x 6 x 1.34"
90% typical. EFE400M: 1W power draw in standby mode
EFE300M
300W to 400W Medical Power Supplies
EN55011, EN55022 Class B (per CISPR.11/22)
EN61000-4-2, -3, -4, -5, -6, -8, -11, -12, -14
5V 2A or 12V 1A (chosen at time of ordering)
<40A at 25C and 230VAC input, Cold Start
12V 1A (Available if no fan option selected)
Automatic recovery upon overload removal
Benefit
EN61000-3-2 Compliant (0.97 typical)
Medical
Instrumentation
Network servers and routers
45 - 63Hz, 440Hz with reduced PFC
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
>16ms at 90VAC input, 75% load
Improved product performance
Less heat dissipated in system
Fits in 1U enclosures
Reduces end system design and cost
(2) -20°C cold start
Medical Safety Certifications (BF Rated)
Fully Featured - including ORing Diode
Universal Input (90 - 264VAC)
Peak Loading (10s)
Suitable for 1U applications
90 - 264VAC, 120 - 350VDC
Method 51.4, Pro I, Cat 1, 9
Cycle AC line to reset
< 1.5% peak-peak
-40 to +85°C
5 - 95% RH
Three Years
None
Yes
3.5 x 6.5 x 1.34"
EFE400M
TBD
39