P40 Tyco, P40 Datasheet

no-image

P40

Manufacturer Part Number
P40
Description
Definite Purpose Magnetic Contactor
Manufacturer
Tyco
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P400-1
Manufacturer:
LEAPFROG
Quantity:
20 000
Part Number:
P4000
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
P4002
Manufacturer:
CHORUS2
Quantity:
115
Company:
Part Number:
P4002-1
Quantity:
104
Part Number:
P4004ED
Manufacturer:
NIKOS
Quantity:
20 000
Part Number:
P4006
Manufacturer:
ST
0
Part Number:
P4006 160U
Manufacturer:
MOT
Quantity:
3 500
Part Number:
P4006BV
Manufacturer:
NIKO-SEM
Quantity:
20 000
Part Number:
P4006R
Manufacturer:
ST
0
Company:
Part Number:
P4009
Quantity:
81
Part Number:
P400X
Manufacturer:
C&D
Quantity:
1 000
Part Number:
P400X
Manufacturer:
SANREX
Quantity:
20 000
Part Number:
P400X
Quantity:
60
Part Number:
P4010
Manufacturer:
ST
0
Part Number:
P4010R
Manufacturer:
ST
0
Part Number:
P401W
Manufacturer:
INFINEON
Quantity:
1 000
Part Number:
P401W
Quantity:
60
Part Number:
P402
Manufacturer:
IR
Quantity:
32
www.DataSheet.co.kr
Features
• AC and DC coils.
• Available with auxiliary switch.
• Variety of main contact terminals.
• For control of motors, power supplies, heating elements and lighting.
Contact Data @ 25°C
Arrangements: Up to 4 Form X (4PST-NO-DM)
Ratings: See contact rating table.
Material: Silver-cadmium oxide.
Expected Life: 200,000 operations at full load.
Minimum Contact Data: 3A @ 120VAC.
Main Contact Ratings
P30 Electrical Discharge Lamp Control: 40A @ 240V (Delta), 40A @ 600V (Wye).
P40 Electrical Discharge Lamp Control: 50A @ 600V (Wye).
Auxiliary Snap-Action Switch
Arrangements: Up to 2 Form C (DPDT).
Rating: 10 amps at 120-250VAC @ 25°C.
Material: Silver.
Initial Dielectric Strength
Initial Breakdown Voltage: 2,200V rms minimum between all elements
Coil Data @ 25°C
Voltage: From 12 to 120VDC, and 24 to 277VAC, 50/60 Hz.
Power: DC, 7 .5 W; AC, 92VA, In rush; 12 VA Sealed.
Duty Cycle: Continuous.
Insulation Class: Class A, standard, Class B available.
Initial Insulation Resistance: 100 megohms, minimum.
Dimensions are shown for
reference purposes only.
Type
P30
P40
Type
P30
P40
Full Load
@ 600V
Motor Rating in Amps, 3Ø3P or 1Ø2P
30A
40A
DC Coil
AC coil: 2 million operations, mechanical.
DC coil: 10 million operations, mechanical.
1Ø2P
3Ø3P
1Ø2P
3Ø3P
@ 240V
180A
240A
Motor Rating in Horsepower
Locked Rotor
and between all elements to ground.
@480V
200A
150A
@ 120V
1.5HP
3HP
2HP
5HP
@ 600V
120A
160A
Dimensions are in inches over
(millimeters) unless otherwise
specified.
@ 240V
7 .5HP
10HP
3HP
5HP
Resistive
@ 600V
Rating
40A
50A
AC Coil
@ 440-600V
Tungsten
Rating
@277V
7 .5HP
15HP
40A
50A
Issued 3-03 (PDF Rev. 5-05)
Catalog 1308242
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Coil Data
*Applicable for vertical mounting, but not for upside-down mounting.
Note: Coil suppression is recommended for all DC coil units, particulary 120 and
Operate Data
Must-Operate Voltage: See coil data tables.
Environmental Data
Temperature Range: –55°C to +65°C.
Mechanical Data
Mounting: Universal mounting bracket. See outline drawings.
Termination:
Weight: 3 Pole Models: 25 oz. (709g) approximately.
4 Pole Models: 28 oz. (794g) approximately.
Specifications and availability
subject to change.
P30/P40
Definite Purpose Magnetic Contactor
30/40 Ampere Full Load
40/50 Ampere Resistive
AC & DC Coils
Nominal
AC Voltage
Contacts: Binder screw, box lug, captive pressure plate, combination
Coil: Combination 8-32 screw and .250” (6.35mm) quick connect.
Aux. Switch: .187” (4.75mm) quick connect.
VDC
Rating
120
240VDC coils.
File E22575
File LR15734
12
24
48
240
277
120
24
screw and dual .250” (6.35mm) quick connect, or
combination box lug and dual .250” (6.35mm) quick
connect. See Main Contact Terminal Options photo.
(Ohms ± 10%
Resistance
@ 25° C)
2,110
334
20.8
84
series
50/60 Hz.
Nominal
208/240
110/120
277
24
Operate*
Must
Volts
36
90
18
9
Maximum
Operating
Volts
144
30
57
15
Must Operate*
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
50/60 Hz.
Nominal Voltage
20.4
Current (ma) @
236
177
94
Nominal Coil
577
286
144
57
P&B
Datasheet pdf - http://www.DataSheet4U.net/
823

Related parts for P40

P40 Summary of contents

Page 1

... P30 30A 180A 150A P40 40A 240A 200A P30 Electrical Discharge Lamp Control: 40A @ 240V (Delta), 40A @ 600V (Wye). P40 Electrical Discharge Lamp Control: 50A @ 600V (Wye). Motor Rating in Horsepower Type @ 120V P30 1Ø2P 1.5HP 3Ø3P 3HP P40 1Ø2P 2HP 3Ø ...

Page 2

... Ordering Information Typical Part No. 1. Type: P30 = Definite Purpose Contactor, 30 amp. P40 = Definite Purpose Contactor, 40 amp. 2. Auxiliary Switch Aux. Switch Form C (SPDT Form C (DPDT) 3. Main Contact Arrangement Form X (3PST-NO-DM Form X (DPST-NO-DM) & 1 Form Y (SPST-NC-DB Form X (SPST-NO-DB) & ...

Page 3

... X contact arrangements. Kits for P30 contactors: 3 Form X models - Kit No. 9P30X1 4 Form X models - Kit No. 9P30X2 Kits for P40 contactors: 3 Form X models - Kit No. 9P40X1 4 Form X models - Kit No. 9P40X2 Dimensions are shown for reference purposes only. Catalog 1308242 Issued 3-03 (PDF Rev. 5-05) DC Coil 3 ...