PM4100APD South African Micro-Electronic Systems, PM4100APD Datasheet - Page 6

no-image

PM4100APD

Manufacturer Part Number
PM4100APD
Description
PM4100APD Evaluation Module is Designed to Demonstrate The Functionality of The Sames SA2002E, SA2002H, SA2002P, SA2002D And SA2102D Integrated Circuits.
Manufacturer
South African Micro-Electronic Systems
Datasheet
SA2102D
Bi-Directional Energy Measurement
Uni-Directional Energy Measurement
J14, J15
http://www.sames.co.za
PM4100APD
Name
J17,
J18,
J10
J12
J13
J19
J20
J21
J23
J25
J11
J7
J8
J9
State
A
A
A
A: Setting to A and J20 to + enables the FAST
output mode. Leaving J10 and J20 open disables
FAST mode and enables standard mode.
B
B
A
B. Connect if a stepper motor or counter is to be
connected.
Rated conditions select (
J19 for R2
datasheet for further information. For Fast mode,
any combination except all to +. For different
normal mode settings, refer to the SA2102D
datasheet. Note: On module + = V
“+” : FAST mode enabled. “-” or OPEN: Standard
mode enabled. Also see J10.
CLOSED: Inserting the jumper enables the pulse
stability circuitry. OPEN: Leaving it open disables
the pulse stability circuitry.
“-”
A
Forward
Reverse
Table 7: Jumper options for SA2102D
J4
J5
J3
J4
J5
J3
J4
J5
). Please refer to the SA2102D
J17 for R0, J18 for R1,
DD
A
A
A
A
+
-
A
B
and - = V
SS
6/14
SA4102A
Bi-Directional Energy Measurement
Uni-Directional Energy Measurement
J17, J18,
J19, J21,
J14, J15
Name
J10
J12
J13
J20
J23
J25
J11
J7
J8
J9
Table 8: Jumper options for SA4102A
State
A
A
A
A
B
B
A
Set to B to enable stepper motor or counter
connectors (CON 4 and CON 5)
Rated conditions select (J17 for R0, J18 for R1,
J19 for R2, J21 for R3). Please refer to the
SA4102 datasheet for further information.
Fms (see datasheet). Leave J20 open for fast
pulse output.
Filter output select. Set to + for Averaging filter.
Set to - for Filtered instantaneous output.
A
Forward
Reverse
J4
J5
J3
J4
J5
J3
J4
J5
sames
sames
A
B
A
A
A
A
+
-

Related parts for PM4100APD