3012GCC Cooper Bussmann, Inc., 3012GCC Datasheet

no-image

3012GCC

Manufacturer Part Number
3012GCC
Description
Fused Lighting & Appliance Panelboard Ep Series Coordination Module?
Manufacturer
Cooper Bussmann, Inc.
Datasheet
Fused Lighting & Appliance Panelboard
EP Series Coordination Module™
0310
Coordination Module™ Specifications
Series
EP2M23012GCC
EP2M23024GCC
EP2M23036GCC
EP2M23042GCC
EP2B_3012GCC
EP2B_3024GCC
EP2B_3036GCC
EP2B_3042GCC
EP3M23012GCC
EP3M23024GCC
EP3M23036GCC
EP3M23042GCC
EP3B_3012GCC
EP3B_3024GCC
EP3B_3036GCC
EP3B_3042GCC
EP4M23012GCC
EP4M23024GCC
EP4M23036GCC
EP4M23042GCC
EP4B_3012GCC
EP4B_3024GCC
EP4B_3036GCC
EP4B_3042GCC
** When protected by upstream LPS-RK 200A max, LPJ 200A max or JJS 200A max, otherwise 14kA.
Main breaker option may impact selective coordination. Coordination must be verified analyzing time current curves and available current.
Feed through lugs available upon request
Catalog Symbol: EP
Voltage Ratings: 120/208V, 120/240V, 277/480V
Main Device Type: MLO (200A), Main Circuit Breaker
Enclosure: NEMA 1
Trim: Surface Mount
Agency Information: UL 67, UL 50
* When protected by upstream LPN-RK 100A max, LPJ 200A max or JJN 200A max, otherwise 10kA.
BU-SB091107
120/208V
120/208V
120/208V
120/208V
120/240V
120/240V
120/240V
120/240V
120/240V
120/240V
120/240V
120/240V
120/240V
120/240V
120/240V
120/240V
277/480V
277/480V
277/480V
277/480V
277/480V
277/480V
277/480V
277/480V
Voltage
Rating
(up to 200A)
Current Rating
Short-Circuit
100kA**
100kA**
100kA**
100kA**
100kA**
100kA**
100kA**
100kA**
100kA*
100kA*
100kA*
100kA*
100kA*
100kA*
100kA*
100kA*
100kA*
100kA*
100kA*
100kA*
100kA*
100kA*
100kA*
100kA*
28" W X 36" H X 5.75" D
28" W X 36" H X 5.75" D
28" W X 48" H X 5.75" D
28" W X 48" H X 5.75" D
28" W X 36" H X 5.75" D
28" W X 36" H X 5.75" D
28" W X 48" H X 5.75" D
28" W X 48" H X 5.75" D
28" W X 36" H X 5.75" D
28" W X 36" H X 5.75" D
28" W X 48" H X 5.75" D
28" W X 48" H X 5.75" D
28" W X 36" H X 5.75" D
28" W X 36" H X 5.75" D
28" W X 48" H X 5.75" D
28" W X 48" H X 5.75" D
28" W X 36" H X 5.75" D
28" W X 36" H X 5.75" D
28" W X 48" H X 5.75" D
28" W X 48" H X 5.75" D
28" W X 36" H X 5.75" D
28" W X 36" H X 5.75" D
28" W X 48" H X 5.75" D
28" W X 48" H X 5.75" D
Dimensions
The Cooper Bussmann
saves you time and money by making it easy to
meet NEC
The Cooper Bussmann Coordination Module makes it
simple to achieve and verify selective coordination in a fully
fused system. Utilize published fuse coordination ratios to
select the correct upstream fuse rating. The ratios ensure
coordination for any level of fault current, so short-circuit
current studies are not required to design a selective
coordinated system.
General Information:
• Use Low-Peak
• Locate open fuses with easyID™ neon indicator
• Use to comply with 2008 NEC
coordination
requirements for emergency, legally required standby and
essential electrical systems per sections 700.27, 701.18,
517.26 and 708.54
®
selective coordination requirements.
3-Phase, 4 Wire
3-Phase, 4 Wire
3-Phase, 4 Wire
3-Phase, 4 Wire
3-Phase, 4 Wire
3-Phase, 4 Wire
3-Phase, 4 Wire
3-Phase, 4 Wire
1-Phase, 3 Wire
1-Phase, 3 Wire
1-Phase, 3 Wire
1-Phase, 3 Wire
1-Phase, 3 Wire
1-Phase, 3 Wire
1-Phase, 3 Wire
1-Phase, 3 Wire
3-Phase, 4 Wire
3-Phase, 4 Wire
3-Phase, 4 Wire
3-Phase, 4 Wire
3-Phase, 4 Wire
3-Phase, 4 Wire
3-Phase, 4 Wire
3-Phase, 4 Wire
Configuration
®
fuses and a 2:1 ratio to easily achieve
Panel
®
Coordination Module™
®
selective coordination
Number of
Circuits
12
24
36
42
12
24
36
42
12
24
36
42
12
24
36
42
12
24
36
42
12
24
36
42
Data Sheet #1149
Main Lug Only
Main Lug Only
Main Lug Only
Main Lug Only
Main Lug Only
Main Lug Only
Main Lug Only
Main Lug Only
Main Lug Only
Main Lug Only
Main Lug Only
Main Lug Only
Main Breaker
Main Breaker
Main Breaker
Main Breaker
Main Breaker
Main Breaker
Main Breaker
Main Breaker
Main Breaker
Main Breaker
Main Breaker
Main Breaker
Page 1 of 19
Option
Form No. EP
Main

Related parts for 3012GCC

Related keywords