MSCT-1S3E Banner Engineering Corp., MSCT-1S3E Datasheet - Page 7

no-image

MSCT-1S3E

Manufacturer Part Number
MSCT-1S3E
Description
For Mini-screen Systems With Edm And Selectable Trip/latch Output
Manufacturer
Banner Engineering Corp.
Datasheet
Figure 23 Replacement
Figure 23b(s). Generic MaAchine Interface, MINI-SCREEN MSC..-1T3E Systems with the MSA-RM-2 relay pack
User must comply with all product manuals
and relevant regulations.
All MINI-SCREEN System output
contacts (FSD1, FSD2, and SSD)
must be used. The generalized wiring
configuration shown here is provided
only to illustrate the importance of proper
installation. The actual details of wiring of
the MINI-SCREEN system to any particular
machine is solely the responsibility of the
installer and end user.
If arc suppressors are used, they must
be installed as shown across the coils
of the safety relays. Never install arc
suppressors directly across the output
contacts of any safeguarding device.
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
WARNING . . .
WARNING . . .
WARNING . . .
Suppressors
MSC..-1S..E
Arc
Supplement: MINI-SCREEN Models with Selectable Trip/Latch Output
L (V ac)
+ (V dc)
or
for Power Monitoring
MPCE1
in primary manual.
EDM as described
MPCE 1 MPCE 2
MPCE 1
Optional hookup
Machine
Control
Circuit
MPCE2
MPCE 2
K1
Relay Module
N (V ac) or – (V dc)
L (V ac) or + (V dc)
MINI-SCREEN Control Box
MSA-RM-2
TB4
TB2
TB2
SSD
K2
See Figure 5
Mon a
Mon b
KEY 1
KEY 2
MSC..-1S3E
AUX
CNC
AUX
PE
Jumper Mon a and
Mon b for no
EDM monitoring
See Sections 2.10(s)
and 3.2.1.1(s) on the
installation of the
Key Reset switch.
TB1
FSD2
FSD1
SSD
TB1
TB1
TB1
*Arc Suppressor,
see warning at left.
Earth Ground
MPCE
MSCE
MPCE
2
*
*
*
1
P/N 68980
N (V ac)
– (V dc)
or


Related parts for MSCT-1S3E