MSA150 iccus, MSA150 Datasheet
MSA150
Manufacturer Part Number
MSA150
Description
Msa150 Series 150 Watts Medical Switch Mode Power Supply
Manufacturer
iccus
Datasheet
1.MSA150.pdf
(2 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
MSA150024A
Manufacturer:
Knowles Corporation
Quantity:
1
A
1-888-357-2280
saleselpac@iccus.com
www.iccus.com
+44.1383.432920
saleseurope@iccus.com
As a Global Supplier of Power Sup-
plies, we are committed to meet-
ing energy efficiency standards
around the world. That is why we
have partnered with the ENERGY
STAR® Program and engineer our
Elpac Power Systems
strict energy-efficiency guidelines
established by the EPA and the US
Department of Energy (DOE). The
Energy Star program has devel-
oped International partnerships
with countries and organizations
in major global markets. Those
participating in the program
include Australia, Canada, Euro-
pean Union, European Free Trade
Association, Japan, New Zealand,
and Taiwan.
Furthering our International com-
mitment, we have signed the EU
Code of Conduct on Efficiency
of External Power Supplies. Our
Elpac Power Systems
series meets the efficiency stan-
dards of the International ENERGY
STAR® program and the EU Code of
Conduct.
TECHNICAL SUPPORT
WORLDWIDE
EUROPE
ENERGY STAR PARTNER
TM
TM
to meet
MSA150
Notes
**Ripple and noise measured with 20MHz bandwidth; 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor.
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Zero Load
Power Consumption
Earth Leakage Current
Patient Leakage Current
Input
*visit www.iccus.com for complete details
5-YEAR LIMITED WARRANTY*
85 – 264VAC
100 – 240VAC Nominal
47 – 63Hz
<2A rms
<37A at 230VAC cold start
>0.97
<0.5W
<150µA @ 132VAC @ 60Hz
<250µA @ 264VAC @ 60Hz
<50µA @ 132VAC @ 60Hz
<75µA @ 264VAC @ 60Hz
Medical Switch Mode Power Supply
MSA150 Series
Output Voltage
Total Regulation
Minimum Load
Start-Up Delay
Hold-Up Time
Ripple & Noise
Over Voltage Protection
Over Temperature Protection
Over Current Protection
Short Circuit Protection
Output
▪
▪
▪
▪
▪
▪
▪
▪
▪
High Efficiency
Up to 180W with Forced Air
High Power Density 9.8W/in³
Lifetime Expectation >5 years
Hold-Up Time >25ms at full load
Medical Approval - EN60601-1 Class I
ENERGY STAR Level V
EISA Compliant
CEC Compliant
See Table
+/-5%
No minimum load required
<1.5s
>25ms at any
input voltage
<1% pk-pk **
110 – 135%
Active - Recoverable; plus
Passive - Non Recoverable
120 – 180%
Shutdown, auto-restart
(hiccup mode)
150 Watts