I Scan operation
q Push [V/M] to select memory mode or VFO mode, if nec-
w Make sure the squelch level is set to the threshold point.
e Push [SCAN] to start scan.
r Push [SCAN] again to stop the scan.
ï NORMAL SCAN
•Memory lock scan
Repeatedly scans memory
channels except skip (lockout)
channels.
essary.
• “
• Set a squelch level (01 to 25) where the noise is muted.
• To change the scan direction, turn [DIAL].
• “SCAN (or P SCAN)“ flashes while scaning.
NOTE: Normal scan or Priority scan is pre-programmed
by cloning. Please ask your dealer or system operator for
details.
MR
” appears on the memory mode.
250 msec.
Mch 20
Mch 2*
Mch 1
Mch 3
*: Lockout ch
SKIP
• VFO scan
Repeatedly scans all
frequencies over the entire
band.
Scan step is minimum channel
spacing. (eg 25 kHz or 8.33*
kHz)
ï PRIORITY SCAN
•Priority memory scan
While scaning on a memory
mode, priority watch checks
for a signal on the selected
priority channel every 250 m
sec except lockout channel.
SCAN OPERATION
*Except USA version
lowest
frequency
250 msec.
Priority
ch
Start
SKIP
Scan
Jump
250 msec.
*: Lockout ch
Mch 20
Mch 2*
Mch 1
Mch 3
highest
frequency
3
6

Related parts for IC-A110