CD5A Banner Engineering Corp., CD5A Datasheet - Page 3

no-image

CD5A

Manufacturer Part Number
CD5A
Description
Programmable Modulated Amplifer And Control Modules For Use With Sp12 Series Preamplifed Remote Photoelectric Barrel Sensors Maxi-amp? Cd Series
Manufacturer
Banner Engineering Corp.
Datasheet
2) Logic Level NPN Output (CD3 models)
1) Hookup of SP12 Series Sensors (all models)
SP12 Series sensors are especially designed for use with CD Series modules. The basic hookup is given here. Each MAXI-AMP™ CD Series module supports
use of one pair of SP12 Series sensors. CD5 Series module models also support use of a GATE or INHIBIT sensor at pin #9 (below, this page).
The AUXILIARY terminal (#9) of models CD3A, CD3B, CD3RA and
CD3RB modules offers a logic-level NPN (current sinking) output which
may be used as a fast-response solid-state inhibit signal to the AUXILIARY
input of MAXI-AMP CD5, CL5, CM5, or CR5 Series modules. This output
may also serve as an input to any
MICRO-AMP™, Plug Logic, or CL
Series logic module. In addition,
this output may interface to other
dc devices or circuits like counters,
rate meters, or programmable logic
controllers. Switching capacity is
20mA at 12V dc.
The example here shows the use of
SP12 Series sensors and a CD3 mod-
ule to provide inspection informa-
tion, with the SP300D functioning
as a product (GATE) sensor.
3) Power for External Devices (all models)
External 10 to 30V dc devices such as
self-contained sensors may be connected
between terminals #3 (+) and #1 (-) of
any CD series MAXI-AMP module.
Terminal #3 offers 40mA maximum.
This is sufficient to power most Banner
self-contained dc sensors.
As the example at the right illustrates, the
current sinking output of a self-contained
sensor powered by the MAXI-AMP may
be used as the input to the AUXILIARY
terminal of a CD5 module.
SP12 Sensor Hookup to CD Series MAXI-AMP™ Modules
SUPPLY
Models with electromechanical relay contacts
AC Load
Common
SUPPLY
DC Load
Output
Load
SPDT
Relay
Models with isolated solid-state contacts
AC
5A
AC
*
*105 to 130V ac or 210 to 250V ac, 50/60Hz, depending on model. To power the MAXI-AMP™ module from a dc supply,
connect +12 to 28V dc at 70mA to terminal #3 and dc common to terminal #1. Make no connection to terminal #7 or #8.
*
4
6
8
5
7
5
7
4
6
8
CD3RA
CD3RB
CD5RA
CD5RB
CD3A
CD3B
CD5A
CD5B
Supply
Supply
AC
AC
Supply
AC
7
4
5
8
4
5
6
7
8
6
4
5
6
7
8
11
10
11
2
1
10
3
9
3
2
1
9
NOTE: Black wire from
LED + (white)
LED - (blue)
COMMON (black)
PT - (blue)
PT + (brown)
LED + (white)
LED - (blue)
COMMON (black)
PT - (blue)
PT + (brown)
models
CD3
models
CM5
AUX
is not used
CD5
models
AUX
SE612
+15V dc @40mA
Inhibit
11
10
11
10
3
2
1
9
3
2
1
9
11
10
3
2
1
9
green
white
black
blue
brown
Inhibit
See Hookup Diagram #1 (above) for load and power connection information.
white
green
black
green
+15V dc
red
white
black
blue
brown
White
(#3)
SE612
SP12SELQD
SP12SELQD
(Interrogate)
Brown
Gate
SP12 Series Emitter
Blue
(#1)
SP12 Series Emitter
(Inspection)
DATA
SP300D
SP12SRLQD
SP12SRLQD
(Inspection)
(Interrogate)
Data
GATE
SP12 Series Receiver
Typically, the CM5 module would be
programmed for the ONE-SHOT or
DELAYED ONE-SHOT logic func-
tion. If the SP12 pair "sees" an ac-
ceptable condition when the SP300D
senses the leading (or trailing) edge
of a product, the CD3 will inhibit a
reject pulse from occuring.
SP12 Series Receiver
3

Related parts for CD5A