EK18 Apex Microtechnology Corporation, EK18 Datasheet
EK18
Related parts for EK18
EK18 Summary of contents
Page 1
... Some components will simply be omitted, while others require installation of a jumper to complete the signal path. Only components unique to the EK18 are provided in this kit. Hardware similar to that shown in figure 1 must be obtained locally. BEFORE YOU GET STARTED * All Apex amplifiers should be handled using proper ESD precau- tions ...
Page 2
... EK18 ASSEMBLY During assembly refer to Figure 1 and Figure 4. 1. From the DUT of the PCB insert and solder the 12 cage jacks. Also solder the cage jacks from the circuit side as well, making sure the cage jack remains flush with the component side of the PCB ...
Page 3
... The large terminal pads can be used to solder wire connections or bannana jacks. Note that the EK18 Evaluation Kit uses the same circuit board as the EK15 Evaluation Kit intended for the apex model SA08. As such the designations on the PCB are those for the SA08. The SA18 is a half bridge version of the SA08 and the SA18 is identical in design except for that fact ...
Page 4
... JUMPERED PWR I LIM /SHDN GND EK18U REV. A JUNE 1999 © 1999 Apex Microtechnology Corp. EVALUATION KIT FOR SA18 PIN-OUT The schematic of Figure 3 can be used to verify the functionality of your amplifier and help you gain a familiarity with proper operation. At Out with respect to ground, you should observe ...