FM24C02A Shanghai Fudan Microelectronics Co., Ltd., FM24C02A Datasheet - Page 8

no-image

FM24C02A

Manufacturer Part Number
FM24C02A
Description
2-wire Serial Eeprom
Manufacturer
Shanghai Fudan Microelectronics Co., Ltd.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FM24C02A-G
Manufacturer:
Kingbright
Quantity:
12 000
Part Number:
FM24C02A-SO-T-G
Manufacturer:
FM进口
Quantity:
20 000
Company:
Part Number:
FM24C02A-SO-T-G
Quantity:
300
Device Operation
CLOCK and DATA TRANSITIONS: The SDA pin is
normally pulled high with an external device. Data on
the SDA pin may change only during SCL low time
periods (refer to Figure 4). Data changes during
SCL high periods will indicate a start or stop
condition as defined below.
START CONDITION: A high-to-low transition of SDA
with SCL high is a start condition which must
precede any other command (refer to Figure 5).
STOP CONDITION: A low-to-high transition of SDA
with SCL high is a stop condition. After a read
sequence, the stop command will place the EEPROM
in a standby power mode (refer to Figure 5).
ACKNOWLEDGE: All addresses and data words are
serially transmitted to and from the EEPROM in 8-bit
words. The EEPROM sends a zero to acknowledge
that it has received each word. This happens
Bus Timing
Figure 2.SCL: Serial Clock, SDA: Serial Data I/O
FM24C02A 2-wrie Serial EEPROM
SDA
OUT
SCL
SDA
IN
t
SU.STA
t
HD.STA
t
LOW
t
F
t
AA
t
HD.DAT
t
HIGH
t
LOW
during the ninth clock cycle. Following receipt each
word from the EEPROM, the microcontroller should
send a zero to EEPROM and continue to output the
next data word or send a stop condition to finish the
read cycle.
STANDBY MODE: The FM24C02A features a
low-power standby mode which is enabled: (a) upon
power-up and (b) after the receipt of the stop bit and
the completion of any internal operations.
DEVICE RESET: After an interruption in protocol,
power loss or system reset, any two-wire part can
be reset in following these steps:
1. Clock up to 9 Cycles,
2. Look for SDA high in each cycle while SCL is
3. Create a start condition as SDA is high.
Ver 1.1
high and then,
t
t
SU.DAT
DH
t
R
Data Sheet
t
SU.STO
t
BUF
8

Related parts for FM24C02A