PS2406 Martek Power, PS2406 Datasheet

no-image

PS2406

Manufacturer Part Number
PS2406
Description
Input Voltage Total Power Output 85-264 264 Watts 48v1, 48v2 & 12v
Manufacturer
Martek Power
Datasheet
Input Voltage
Total Power
Output
SPECIAL FEATURES
ENVIRONMENTAL
Ambient Operating Temperature: 0 to +55 C full rating.
Humidity: Up to 95% non-condensing
Storage Temperature: -20 to +85 C
Temperature coefficient:
Cooling: Two 10CFM internal fans. Air flow from front to back.
PS2406
85-264 VAC input with under voltage lockout
Active PFC compliant to EN61000-3-2
UL, CSA, BABT Recognized, CE CB (pending)
Fully protected
No load operation
Fully operational with one fan failure
48V1, 48V2 & 12V
264 Watts
85-264
0.01% / C
ELECTRICAL SPECIFICATIONS
Input……………85 -264 VAC; 47-63Hz;
Inrush Current (264 Vac)…………< 15A peak
Isolation………………..4242VDC (Input to Output)
Susceptibility specifications:
EN 61000-3-2 AC Input line harmonic limits
Complies with EN55022 & FCC Class A with minimum 12 dB
margin
Efficiency………………82% min.
Output
DC Output……………Maximum continuous output power 264W
Line / Load Regulation……< 2%
Ripple and Noise < 1% of output voltage
Transient Response..…2% Maximum deviation
MECHANICAL
9.0” L x 3.3” H x 3.4” W (228.6 mm x 83.8 mm x 86.4 mm)
Input Connector……… IEC 320
Output Connector
Weight: < 5 lbs
Status signals and indicators
Power Fail (open collector)
PS Fan Fail (open collector)
System Fan Fail (open collector)
Visual LED indicators identify power supply status.
Green LED indicates outputs are in regulation
Red LED indicates fault
Power Factor >0.99
Two DB9 and one micro fit
Rev 1

Related parts for PS2406

PS2406 Summary of contents

Page 1

... PS2406 Input Voltage 85-264 Total Power 264 Watts Output 48V1, 48V2 & 12V SPECIAL FEATURES 85-264 VAC input with under voltage lockout Active PFC compliant to EN61000-3-2 UL, CSA, BABT Recognized (pending) Fully protected No load operation Fully operational with one fan failure ENVIRONMENTAL Ambient Operating Temperature +55 C full rating ...

Page 2

Output Over voltage protection – (Latching) Over current protection – (Hiccup) Over temperature protection – (Hiccup) Short Circuit Protection…......Will withstand a continuous short without damage. Minimum Load Rqmt….…No minimum load. No Load Operation……….No damage to supply when operating at no ...

Page 3

Mechanical Outline Rev 1 ...