PS2427 Martek Power, PS2427 Datasheet

no-image

PS2427

Manufacturer Part Number
PS2427
Description
Total Power Input Voltage Output 60.3 Watts 100-480 Vac ?10% 9v @ 6.7a
Manufacturer
Martek Power
Datasheet
PS2427
Total Power
Input Voltage
Output
SPECIAL FEATURES
ENVIRONMENTAL
Ambient Operating Temperature: -40 to +75 C continuous duty, full rating.
Humidity: Up to 95% non-condensing
Temperature coefficient: 0.01% / C
Storage Temperature: - 45 to +85 C
Cooling: Convection cooled
100-480 VAC 10% input
IEEE C62.41 category C (overvoltage class C environments)
Hybrid surge suppression
Line filters
EN55022 Class B EMI
Gas discharge tubes/spark gaps
MOV’s
CC Class dual fusing
Designed for harsh environment
- 40°C to +75°C operating temperature
Can be mounted in a fully enclosed chassis with baseplate
100-480 VAC 10%
9V @ 6.7A
60.3 Watts
ELECTRICAL SPECIFICATIONS
Input
Input……………100 -480 VAC 10%; 50-60Hz;
Inrush Current (264 Vac)…………<30 Amps peak
Isolation………………..500VDC (Input to Output)
Susceptibility specifications:
EN 61000-3-2 AC Input line harmonic limits
Complies with EN55022 & FCC Class B with minimum 6 dB
margin
Efficiency………………> 75% typical at full load
Output
DC Output…………….Maximum continuous output power
60.3 Watts. See Voltage/Current Rating Chart.
Line / Load Regulation… …..<2%
Ripple and Noise < 2% typical
Transient Response…2% Maximum deviation
MECHANICAL
7.38” L X 1.265” Max / 1.245” Min H (at heatsink) X 5.71” W
(187.5 mm X 32.1 / 31.6 mm X 145.2 mm)
Input connector: Fast-On
Output connector: Molex Mini Fit P/N 43879-0023
Status signals and Indicators:
N/A
Rev 1

Related parts for PS2427

PS2427 Summary of contents

Page 1

... PS2427 Total Power 60.3 Watts Input Voltage 100-480 VAC 10% Output 9V @ 6.7A SPECIAL FEATURES 100-480 VAC 10% input IEEE C62.41 category C (overvoltage class C environments) Hybrid surge suppression Line filters EN55022 Class B EMI Gas discharge tubes/spark gaps MOV’s CC Class dual fusing Designed for harsh environment - 40° ...

Page 2

Output Over voltage protection 130% (Hiccup) Over current protection 130% (HIccup) Over temperature protection reset with hysteresis Short Circuit Protection…..Will withstand a continuous short without damage. Minimum Load Rqmt……See Voltage/Current chart. No Load Operation………..No damage to supply when operating at ...

Page 3

Rev 1 ...