PS2396 Martek Power, PS2396 Datasheet

no-image

PS2396

Manufacturer Part Number
PS2396
Description
Total Power Input Voltage Outputs 30 Watts 90-277 Vac One
Manufacturer
Martek Power
Datasheet
PS2396
Total Power
Input Voltage
Outputs
SPECIAL FEATURES
ENVIRONMENTAL
Ambient Operating Temperature: - 40 C to +70 C continuous duty, full rating.
Humidity: 5 to 100% non-condensing
Temperature coefficient: 0.01% / C
Storage Temperature: - 50 to +85 C
Cooling: Convection cooled
Wide input voltage
IEEE C62.41 category C (overvoltage class C environments)
Hybrid surge suppression
Line filters
EN55022 Class B EMI
Gas discharge tubes/spark gaps and MOV’s
CC Class dual fusing
Designed for harsh environment
- 40°C to +70°C operating temperature
EN60950 and UL 1449 compliant
Water tight connectors and enclosure
90-277 VAC
30 Watts
One
ELECTRICAL SPECIFICATIONS
Input
Input……………90 -277 VAC; 50-60Hz ±3Hz
Isolation………………..4242VDC (Input to Output)
Susceptibility specifications:
Complies with EN55022 & FCC Class B with minimum 6 dB
margin
Efficiency………………> 70% typical at full load
Output
DC Output…………….Maximum continuous output power
30 Watts. See Voltage/Current Rating Chart.
Line / Load Regulation…..…..<1% typical
Ripple and Noise……..<100 mV (P-P)
Transient Response……..2% Maximum deviation;
MECHANICAL
6.75” L X 2.25” H X 4.76” W (171.4mm X 57.1mm X 120.6mm)
NEMA 4 Aluminum Alloy enclosure
Rev 2

Related parts for PS2396

PS2396 Summary of contents

Page 1

... PS2396 Total Power 30 Watts Input Voltage 90-277 VAC Outputs One SPECIAL FEATURES Wide input voltage IEEE C62.41 category C (overvoltage class C environments) Hybrid surge suppression Line filters EN55022 Class B EMI Gas discharge tubes/spark gaps and MOV’s CC Class dual fusing Designed for harsh environment - 40° ...

Page 2

Output Over voltage protection 130% (Hiccup) Over current protection 130% (Hiccup) Over temperature protection reset with hysteresis Short Circuit Protection…..Will withstand a continuous short without damage. Minimum Load Rqmt……None No Load Operation………..No damage to supply when operating at no load. ...

Page 3

Rev 2 ...