If you use this timer under harsh environment, please order above sealed type (IP65 type). IP65 type — Protection dust and water jet splay on the front face.
38
PM4H-A
PM4H-S
PM4H-M
1.890
Type
48
8 operation modes
• Pulse ON-delay
• Pulse Flicker
• Pulse ON-flicker
• Differential ON/OFF-delay (1) (2)
• Signal OFF-delay
• Pulse One-shot
• Pulse One-cycle
Power ON-delay
5 operation modes
(With instantaneous contact)
• Power ON-delay
• Power Flicker
• Power ON-flicker
• Power One-shot
• Power One-cycle
Pin type
1.890
48
Operation mode
62.5
2.461
Screw
terminal type
mm
inch
Relay
Timed-out
2 Form C
Relay
Timed-out
2 Form C
Relay
Timed-out
1 Form C
Instantaneous
1 Form C
arrangement
Contact
UL File No.: E122222
CSA File No.: LR39291
Features
• 100-240V AC free-voltage input, 48-125V DC type available
• Short body — 62.5mm
• Front panel of IP65 type is protected against water-splash and dust
• Built-in Screw terminals
• 0 setting instantaneous output operation
• Multiple time ranges — 1 s to 500 h (Max.)
• 8 different operation modes: (PM4H-A)
• Compliant with UL/CSA, CE and LLOYD
Screw terminal type is used for easy wiring and reducing additional cost for
... Screw terminal type is used for easy wiring and reducing additional cost for accessories. • 0 setting instantaneous output operation • Multiple time ranges — 500 h (Max.) • 8 different operation modes: (PM4H-A) • Compliant with UL/CSA, CE and LLOYD Contact Protective Time range ...
... IP65 on front panel (using rubber gasket ATC18002) <only for IP65 type> 100g 3.527 oz 110g 3.880 oz (Screw terminal type) 09/2009 PM4H-A/PM4H-S/PM4H-M All types of PM4H timer have multi-time range. 16 time ranges are selectable 500h (Max. range) is controlled. PM4H-M Power ON-delay ...
... Voltage should not be applied to the various inputs (reset, start, and stop) of (–) the PM4H-A multi-range timer. These inputs should be input without voltage. PM4H-A Output indicator LED Hand Set dial Operation mode indicator Operation mode selector Selectable from 8 operation modes ...
... PM4H-A/S/M Operation mode PM4H-A Operation type • If using a time-limit start when the power is turned on, and a reset when the power is turned off, pins (screw-tightening pins x and c) should be shorted ahead of time. • Turn the operation mode selector switch to the If pins (screw-tightening pins x and c) are shorted (the start input ...
... PM4H-A/S/M Operation type • If using a time-limit start when the power is turned on, and a reset when the power is turned off, pins (screw-tightening pins x and c) should be shorted ahead of time. • Turn the operation mode selector switch to the When pins (screw-tightening pins x and c) are shorted (the start ...