80C32 Philips Semiconductors, 80C32 Datasheet - Page 18
![no-image](/images/manufacturer_photos/0/5/522/philips_semiconductors_sml.jpg)
80C32
Manufacturer Part Number
80C32
Description
CMOS single-chip 8-bit microcontrollers
Manufacturer
Philips Semiconductors
Datasheet
1.80C32.pdf
(56 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
80C32-16
Manufacturer:
MHS
Quantity:
4 600
Company:
Part Number:
80C32-16
Manufacturer:
MHS
Quantity:
4 600
Part Number:
80C32X2-UM
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
1. Capture/reload occurs only on timer/counter overflow.
2. Capture/reload occurs on timer/counter overflow and a 1-to-0 transition on T2EX (P1.1) pin except when Timer 2 is used in the baud rate
Philips Semiconductors
When Timer 2 is in the baud rate generator mode, one should not try
to read or write TH2 and TL2. As a baud rate generator, Timer 2 is
incremented every state time (osc/2) or asynchronously from pin T2;
under these conditions, a read or write of TH2 or TL2 may not be
accurate. The RCAP2 registers may be read, but should not be
written to, because a write might overlap a reload and cause write
and/or reload errors. The timer should be turned off (clear TR2)
before accessing the Timer 2 or RCAP2 registers.
Table 5 shows commonly used baud rates and how they can be
obtained from Timer 2.
Summary Of Baud Rate Equations
Timer 2 is in baud rate generating mode. If Timer 2 is being clocked
through pin T2(P1.0) the baud rate is:
Table 6. Timer 2 as a Timer
Table 7. Timer 2 as a Counter
NOTES:
1999 Apr 01
80C51 8-bit microcontroller family
8K–64K/256–1K OTP/ROM/ROMless, low voltage (2.7V–5.5V),
low power, high speed (33MHz)
16-bit Auto-Reload
16-bit Capture
Baud rate generator receive and transmit same baud rate
Receive only
Transmit only
16-bit
Auto-Reload
generator mode.
Baud Rate + Timer 2 Overflow Rate
16
MODE
MODE
18
If Timer 2 is being clocked internally , the baud rate is:
Where f
To obtain the reload value for RCAP2H and RCAP2L, the above
equation can be rewritten as:
Timer/Counter 2 Set-up
Except for the baud rate generator mode, the values given for
T2CON do not include the setting of the TR2 bit. Therefore, bit TR2
must be set, separately, to turn the timer on. See Table 6 for set-up
of Timer 2 as a timer. Also see Table 7 for set-up of Timer 2 as a
counter.
INTERNAL CONTROL
INTERNAL CONTROL
Baud Rate +
RCAP2H, RCAP2L + 65536 *
(Note 1)
(Note 1)
OSC
00H
01H
34H
24H
14H
02H
03H
= Oscillator Frequency
8XC51RA+/RB+/RC+/RD+/80C51RA+
[32
[65536 * (RCAP2H, RCAP2L)]]
T2CON
TMOD
8XC51FA/FB/FC/80C51FA
f
OSC
EXTERNAL CONTROL
EXTERNAL CONTROL
32
8XC52/54/58/80C32
Baud Rate
f
OSC
(Note 2)
(Note 2)
0AH
0BH
08H
09H
36H
26H
16H
Product specification