CMA3000-D0X VTI Hamlin, CMA3000-D0X Datasheet - Page 32

no-image

CMA3000-D0X

Manufacturer Part Number
CMA3000-D0X
Description
Cma3000-d0x Series 3-axis Accelerometer
Manufacturer
VTI Hamlin
Datasheet
9.1.2
9.2 Leakage current when VDD - DVIO > 0.3 V
VTI Technologies Oy
www.vti.fi
Acceleration reading without interrupts
Acceleration data reading without interrupts can be used in all operation modes. Acceleration data
is read out faster than CMA3000 can updates the acceleration output registers. When two identical
XYZ acceleration values are received, the data is considered valid. The maximum data reading
periods in different operation modes are presented below in Table 13.
Table 13. CMA3000-D01 maximum reading periods when interrupts are not detected.
Output data rate
CMA3000-D01, MODE bits x10
ODR: 400Hz
CMA3000-D01, MODE bits x01
ODR: 100Hz
CMA3000-D01, MODE bits 011
ODR: 40Hz
CMA3000-D01, MODE bits 100
ODR: 10Hz
ODR = Output Data Rate
Figure 25. Interrupt based CMA3000 acceleration data read timing.
Due to design issue a switch will leak some current, if the VDD will be approx 300 mV higher than
DVIO. Typical leakage currents are according to the Table 14 below.
Table 14 CMA3000-D0X typical DVIO leakage current when VDD-DVIO>0.3V.
VDD/DVIO [V]
Internal acceleration
register update
Acceleration reading
→ corrupted
2.5 / 1.7
3.6 / 1.7
Acceleration data reading period for 3 samples, T
Doc.Nr. 8281000.12
Leakage current [µA]
Acceleration reading
These two acceleration readings result identical
acceleration values →
Maximum reading period
100
25
for 3 samples, T
24.0 ms
90.0 ms
2.4 ms
9.9 ms
This result is accepted
Acceleration reading
r
r
Internal acceleration
register update
Acceleration reading
→ corrupted
CMA3000-D0X Series
Rev. 0.12
32/ 35

Related parts for CMA3000-D0X