VS-60-12 CUI INC, VS-60-12 Datasheet

no-image

VS-60-12

Manufacturer Part Number
VS-60-12
Description
Vs-60-12 Metal Enclosed Switching Power Supply
Manufacturer
CUI INC
Datasheet
DC output voltage
Output V. tolerance
Output rated current
Output current range
Ripple & noise
Line regulation
Load regulation
DC output power
Efficiency
DC voltage adj.
Input voltage range
AC current
Inrush current
Leakage current
Overload protection
Over voltage protection
Over temp. protection
Temperature coefficient
Set up, rise, hold up time
Vibration
Withstand voltage
Isolation resistance
Working temp., humidity
Storage temp., humidity
Dimensions
Weight
Safety standards
EMC standards
Notes:
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise cus-
tomers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for cus-
tomer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s pub-
lished specifications. Nothing will be covered outside of standard product warranty.
Features
·Universal AC input/ Full range
·Short circuit, overload, over-
·Cooling by free air convection
·100% full load burn-in test
·Fixed switching frequency at 50KHz
·2 year warranty
voltage protected
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005
1. All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient
2. Tolerance includes set up tolerance, line regulation, load regulation
3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor
4. Line regulation is measured from low line to high line at rated load
5, Load regulation is measure from 0% to 100% rated load
12V
±1%
5A
0-5A
120mVp-p
±0.5%
±0.5%
60W
76%
±10% rated output voltage
85~264VAC 47~63Hz; 120~370VDC
2A/115V 1A/230V
cold start 30A/115V 60A/230V
<3.5mA/240VAC
105%~150%
type: Hiccup mode, recovers automatically after fault condition is removed
115%~135%
---
±0.03% / °C (0~50°C)
800ms, 50ms, 10ms / 115VAC 300ms, 50ms, 80ms / 230VAC
10~500Hz, 2G 10min./1cycle (1 hour each axes)
I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, for 1 min.
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms min.
-10°C~+60% (refer to output derating curve), 20%-90% RH
-20ºC~+85ºC, 10%~95% RH
6.26x3.82x1.50 inches
1.21 lbs
UL1012, UL1950, TUV EN60950 APPROVED
CISPR22 (EN55022) CLASS B, EN61000-3-2,3; EN61000-4-2,3,4,5,6,8,11 ; ENV50204
VS-60-12 Metal Enclosed Switching Power Supply
(0.55 Kg)
(159x97x38 mm)
www.v-infinity.com
1-866-372-1258

Related parts for VS-60-12

VS-60-12 Summary of contents

Page 1

... V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s pub- lished specifications. Nothing will be covered outside of standard product warranty. V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005 VS-60-12 Metal Enclosed Switching Power Supply (159x97x38 mm) (0.55 Kg) www ...