Description
Splice Sensor
Manufacturer
Pepperl+Fuchs
Subject to reasonable modifications due to technical advances.
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Displays:
LED yellow:
LED green:
LED red:
Switch outputs:
The switch outputs are only active in normal operation!
pin 4:
pin 2:
Output pulse extension
If the teach input (pin 5) is not connected, when switching on the power supply, the sensor operates with output pulse prolongation.
Events, shorter than 120 ms cause an output pulse duration of 120 ms at the Splice output. For sensor operation without pulse prolon-
gation, the teach input (pin 5) has to be connected with
Please note:
This can result in a condition in which more than one switch output is switched through!
TEACH-IN mode
Connecting the teach input (pin 5) with
procedure has to be carried out with base material. In case of inhomogeneous base materials we suggest to teach the sensor with
activated material feeding and a corresponding prolongation of the TEACH-IN procedure.
During the TEACH-IN procedure flashes the yellow LED; the green LED is off.
After returning to the normal operation mode (teach input (pin 5) detached from
cedure was successful or not.
TEACH-IN procedure successful: green LED flashes 3 times
TEACH-IN procedure not successful: red LED flashes 3 times
Notes:
If two or more double sheet controls are used in the immediate vicinity of each other, there may be mutual interference between them,
which can result in improper functionality of the devices. Mutual interference can be prevented by introducing suitable countermeasures
when planning systems. Suitable measures can be:
- Mounting of sound absorbers (foam material)
- mounting of sound separators (sheet metal)
- insallation of the sensors with different directions of sound transmission.
Splice sensor
Detection of splices
Detection of air (no base material)
Splice output
Air output
Power on
+U
B
for at least 500 ms causes the sensor to change into TEACH-IN mode. The TEACH-IN
-U
B
while power supply is switched on.
UGB-18GM50-255-2E3-150MM-V15-Y
+U
B
) the sensor indicates whether the TEACH-IN pro-
Copyright Pepperl+Fuchs, Printed in Germany