D40B Omron Corporation, D40B Datasheet

no-image

D40B

Manufacturer Part Number
D40B
Description
Compact Non-contact Door Switch
Manufacturer
Omron Corporation
Datasheet
Detects the open/closed state of doors
without making contact and has high
resistance to the environment.
Features
Special Actuators and Control Unit to Prevent False
Operation
Safety Category 3 (EN954-1)
Detect Closed Status for Multiple Covers
• Detects the open/closed state of doors without making
• The non-contact operation prevents the creation of particles
• The Actuator and Switch can be washed with water (not
• Small distortions in the door and mechanical discrepancies
• Safety Category 3 (EN954-1).
• A safety output on the Control Unit turns ON when the Special Actuator
• The safety output will not turn ON even if a magnet or magnetic body
• The Control Unit detects failures in the Sensor or connected contactor.
• Up to six Sensors can be connected to each Control Unit.
• Cover open/closed status can be monitored by using a Sensor with an
Compact Non-contact Door Switch
D40B Series
contact by combining a special magnetic Actuator and
Switch. The switching mechanism is not easily disabled.
due to abrasion.
immersible in water). There are no key-holes where dirt can
accumulate, making it easy to keep machinery clean.
can be absorbed in the allowable operating range of the
magnetic Actuator and Switch.
approaches.
approaches.
auxiliary output.
Be sure to read the “Safety Precautions” on page 9 and the
“Precautions for All Safety Door Switches”.
Actuator
D40B
ACTUATO R
ACTUATO R
Sensor
CODED SENSOR
CODED SENSOR
VDE 0660-209
VDE 0660-209
Made in the UK
Made in the UK
D40B
EN 954-1
EN 954-1
EN 1088
EN 1088
IP 67
IP 67
Switch
+
CSM_D40B_DS_E_2_1
Control Unit
1

Related parts for D40B

D40B Summary of contents

Page 1

... Compact Non-contact Door Switch D40B Series Detects the open/closed state of doors without making contact and has high resistance to the environment. • Detects the open/closed state of doors without making contact by combining a special magnetic Actuator and Switch. The switching mechanism is not easily disabled. ...

Page 2

... Auxiliary output None None Rated voltage Model 24 VAC/VDC D40B-J1 24 VAC/VDC D40B-J2 110/230 VAC Model D9M-P1 D40B Cable length Model 3 m D40B-1B3 10 m D40B-1B10 3 m D40B-1D3 10 m D40B-1D10 3 m D40B-2B3 10 m D40B-2B10 3 m D40B-2D3 10 m D40B-2D10 D40B-3D5C 5 m D40B-3E5C 2 ...

Page 3

... Actuator's target marks are aligned and the sensing surfaces have the same orientation. *2. If the approach speed is less than the specified value, the Controller's safety contact output may not turn ON, even if the distance is less than the switching distance. *3. Applies only to the D40B-1D@, D40B-2D@,and D40B-3@5C. Switches with contacts have no polarity. Controller Ratings ...

Page 4

... A2 terminals. Do not connect the power supply to the + and − terminals VDC power supply is used, connect it to the + and − terminals. Do not connect the power supply to the A1 and A2 terminals. D40B D40B-J2 100 mΩ max. (including auxiliary output) --- 590 g High-temperature Type Sensor ...

Page 5

... Dimensions and Terminal Arrangement Sensor (Switch/Actuator) Standard Sensor D40B-1B3 D40B-1B10 D40B-1D3 D40B-1D10 Elongated Sensor D40B-2B3 19 D40B-2B10 D40B-2D3 D40B-2D10 Target mark High-temperature Type Sensor D40B-3D5C D40B-3E5C Target mark 12 48 4.8 25 Two, 4.2 dia 5.5 7.8 Cable diameter: 4.2 dia. (Switch) 19 4.2 4.2 9 Target mark 4.5 4 Cable diameter: 4 ...

Page 6

... Controller D40B-J1 22.5 Twelve, M2.5 2-Pole Controller D40B-J2 45.5 Application Examples Wiring Example for 1 Sensor and 2 Contactors (with D40B-J1): Auto-reset The configuration in this example is for auto-reset and contactor monitoring. Fuse *2 Blue *1 Guard door Yellow *1 Green *1 Red *1 Note: The circuit in this example is equivalent to a Safety Category 3 circuit. ...

Page 7

... Wiring Example for 1 Sensor and 2 Contactors (with D40B-J2): Auto-reset The configuration in this example is for auto-reset and contactor monitoring. Fuse Blue * Guard door Yellow * Green * Red * Note: The circuit in this example is equivalent to a Safety Category 3 circuit. * This example applies to Standard or Elongated Sensors. The wire colors for the High-temperature Type Sensors are different. Refer to “Sensor and Controller Connection Examples” ...

Page 8

... A2 Blue D40B-J1 D40B Blue Yellow White * Black * Red * Auxiliary output D40B-1D@ (Standard Green models) and D40B-2D@ (Elongated models) only − D40B-J2 Blue Yellow + White * Black * Green Red Gray * Auxiliary output − ...

Page 9

... Do not connect loads beyond the rated value to the safety outputs. Serious injury may possibly occur due to loss of required safety functions. Wire D40B properly so that supply voltages or voltages for loads do NOT touch the safety inputs accidentally or unintentionally. !CAUTION Be sure to turn OFF the power before performing wiring. ...

Page 10

... Precautions for Correct Use Description 1. The D40B-series Sensor (switch and actuator) must only be used with the D40B-series Controller. 2. The D40B-series guard interlock switch system is self monitoring and comprises a magnetic actuator and switch connected via two wiring channels to a Controller. Mounting Direction of Switch and Actuator The Sensor will not operate properly if the Switch and Actuator approach each other diagonally ...

Page 11

... OMRON cannot accept responsibility for a failure of this device if the procedures given in this sheet are not implemented used outside the recommended specifications in this sheet. 5. Guard stops and guides must be fitted to protect the D40B-series Sensor from shock. Fuse Replacement Method (D40B-J2 Only) • ...

Page 12

... OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ Read and Understand This Catalog Warranty and Limitations of Liability Application Considerations Disclaimers In the interest of product improvement, specifications are subject to change without notice. (c)Copyright OMRON Corporation 2008 All Right Reserved. 2008.12 ...

Related keywords