RL28-54-G-Z Pepperl+Fuchs, RL28-54-G-Z Datasheet - Page 4

no-image

RL28-54-G-Z

Manufacturer Part Number
RL28-54-G-Z
Description
Retroreflective Sensor With Polarization Filter For Clear Object
Manufacturer
Pepperl+Fuchs
Datasheet
4
Mounting instructions:
The sensor is held in place by two pass-through drill holes for M5. The surface underneath must be flat to prevent the housing
from moving when it is tightened into position. We recommend securing the nuts in place with spring screws to prevent the sen-
sor from going out of adjustment.
Outdoor mounting:
The sensors must be protected from shock and splashed water. It may be necessary to provide a covering.
Adjustment:
Align the unit to the reflector in the "N“ switch setting. The yellow LED must be lit constantly. Move the switch to the "T“ setting
and wait for about 1 sec. until the yellow LED starts flashing slowly.
Move the switch to the setting for the desired contrast detection level: "I“ for 10%, "II“ for 18%, "III“ for 40%.
or
In switch setting "T“, select the appropriate contrast detection level by applying a pulse through the control lead to connection
pin 5 (see "TEACH-IN“).
Contrast detection levels:
The output becomes inactive if dirt and dust make it impossible to readjust the setting. In this case the yellow LED will flash
quickly.
If dirt and dust continue to accumulate, detection of slight contrasts can no longer be guaranteed.
Additional information
Type
-Z
Retroreflective sensor with polarization filter for clear object
Subject to modifications without notice
Pepperl+Fuchs Group
www.pepperl-fuchs.com
Description
one shot timer
fa-info@us.pepperl-fuchs.com
USA: +1 330 486 0001
Germany: +49 621 776-4411
fa-info@pepperl-fuchs.com
fa-info@sg.pepperl-fuchs.com
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
Notes
Fixed time interval 0.02 s
RL28-54-G-Z/47/112

Related parts for RL28-54-G-Z