ACSL-6xx0 Agilent / Hewlett-Packard, ACSL-6xx0 Datasheet - Page 6

no-image

ACSL-6xx0

Manufacturer Part Number
ACSL-6xx0
Description
(ACSL-6xx0) Multi-Channel and Bi-Directional / 15 MBd Digital Logic Gate Optocoupler
Manufacturer
Agilent / Hewlett-Packard
Datasheet
6
Regulatory Information
Insulation and Safety Related Specifications
Parameter
Minimum External Air Gap (Clearance)
Minimum Externa l Tracking(Creepage)
Minimum Internal Plastic Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index) CTI
Isolation Group
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (Option X6X Only)
Description
Installation Classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150V rms
for rated mains voltage ≤ 300V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b *
V
Test with t
Input to Output Test Voltage, Method a *
V
T
Highest Allowable Overvoltage *
(Transient Overvoltage, t
Safety Limiting Values
(Maximum values allowed in the event of a failure)
Case Temperature
Input Current
Output Power
Insulation Resistance at T
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2,
for a detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.
m
IORM
IORM
= 60 sec, Partial Discharge < 5 pC
x 1.875 = V
x 1.5 = V
m
= 1 sec, Partial Discharge < 5 pC
PR,
PR
Type and Sample Test,
, 100% Production
ini
S
= 10 sec)
, V
IO
= 500V
Symbol
L(I01)
L(I02)
Symbol
V
V
V
V
T
I
P
R
S,INPUT
IORM
PR
PR
IOTM
S
S,OUTPUT
IO
Value
4.9
4.5
0.08
175
IIIa
Units
mm
mm
mm
Volts
ACSL-6XX0-X6X
I-IV
I-III
55/100/21
2
560
1050
840
4000
175
150
600
10
9
Conditions
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path through body
Insulation thickness between emitter and detector;
also known as distance through insulation
DIN IEC 112/VDE0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Units
V
V
V
V
°C
mA
mW
peak
peak
peak
peak

Related parts for ACSL-6xx0