Page 1
... Tel : (+852) 2565 6979 Fax : (+852) 2565 0319 Email : sales@jlworld.com Website : www.jlworld.com Integrated, Absolute Pressure Sensor The MPS-301A series pressure sensor is a hybrid device containing pressure sensing element and an ASIC for signal conditioning. The sensor element is fabricated using bulk micromachining technology. ...
Page 2
... MPS-301A Integrated, Absolute Pressure Sensor TECHNICAL DATA Specification Min. Operating -20 Temperature Storage -30 Temperature - Proof Pressure - - 2.7 Supply Voltage* 4.75 * Note: Both 3V and 5V versions are available. Product is calibrated and tested at 3V unless otherwise specified. BASIC PERFORMANCE Temperature=22±2°C, Relative humidity=45±5% Specification Supply Current @ 3V ...
Page 3
... MPS-301A Integrated, Absolute Pressure Sensor SPI / I²C OUTPUT – INTERFACE OPTIONS S & I Specification Min. Typ. SPI Clock Rate - Zero Pressure - 888 Output (Offset) Full Scale Output - 6666 Full Scale Span - 5DDE Accuracy (25 ±3°C - & 75-110 kPa) Accuracy (0-85°C & - 75-110 kPa) ...
Page 4
... MPS-301A Integrated, Absolute Pressure Sensor ELECTRICAL & PIN LAYOUT PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 SPECIFICATION NOTES 1. Operating and storage temperature to strictly not exceed stated values. 2. Pressure unit conversion --- 1 atm=101.325 kPa=1013.25 hPa=14.504 psi. 3. Operating pressure and temperature. The nominal pressure under which the device can be exposed under normal operating conditions ...
Page 5
... MPS-301A Integrated, Absolute Pressure Sensor INTERFACE DESCRIPTION (OPTION I) 2 For I C communication only two pins are used namely SDA (Pin 5) and SCL (Pin 4). The sensor behaves as a slave in this communication. 2 The I C protocol is defined as follows: i) Idle period : During inactivity the SDA and SCL are pulled to supply voltage Vdd ii) Start Condition: A high to low transition on SDA while SCL is high indicates a start condition ...
Page 6
... MPS-301A Integrated, Absolute Pressure Sensor SCL SDA T1 T2 SCL SCK T6 TIMING SPECIFICIATIONS (I Parameter SCL Clock Frequency Bus Free time between start and stop condition Hold Time Start Condition High Period SCL/SDA Low Period SCL/SDA Setup Time Stop Condition Setup Time Repeated Start ...
Page 7
... MPS-301A Integrated, Absolute Pressure Sensor SPI INTERFACE DESCRIPTION – OPTION’ S SPI PIN SIGNALS There are four I/O signals associated with SPI transfers: SCK (pin 4), MISO (pin 2), MOSI (used by the manufacturer for calibration purposes only) and SS (pin 3). SCK is an input pin for the clock signal from the master which synchronizes the data transfer between the master and slave devices ...
Page 8
... MPS-301A Integrated, Absolute Pressure Sensor Parameter Description T1-T2 SS delay before first SCK Pulse T2-T3 SCK Clock Period Note 1: Data must be sampled on the rising edge of the SCK Note 2: There will be a dummy pulse starting from the middle of the 7 the next falling edge of the SCK. This pulse should be ignored. ...
Page 9
... MPS-301A Integrated, Absolute Pressure Sensor MECHANICAL DIMENSIONS (9mm by 9mm, round cap MTCM Top View e = 1.27mm BASIC COMMON DIMENSION (mm) SYMBOL MINIMUM A 5.000 A1 2.900 A2 0.550 A3 1.450 D 8.950 D1 6.900 E 8.950 E1 2.400 E2 --- W1 0.219 W2 0.754 W3 2.029 0.783 W4 4.952 W5 Y1 1.543 Y2 0.077 3.680 Y3 1907 Westlands Centre, 20 Westlands Road, Quarry Bay, Hong Kong Tel : (+852) 2565 6979 Email : sales@jlworld ...