B121EW01_V5 AUO, B121EW01_V5 Datasheet - Page 27

no-image

B121EW01_V5

Manufacturer Part Number
B121EW01_V5
Description
LCD MODULE
Manufacturer
AUO
Datasheet
www.DataSheet4U.net
9. Reliability
Note1: According to EN61000-4-2 , ESD class B: Some performance degradation allowed. No data lost
Note2: CCFL Life time: 10,000 hours minimum under normal module usage.
Note3: MTBF (Excluding the CCFL): 30,000 hours with a confidence level 90%
Temperature
Humidity Bias
High Temperature
Operation
Low Temperature
Operation
On/Off Test
Hot Storage
Cold Storage
Thermal Shock Test -40℃/20 min ,65℃/20 min 300cycles
Hot Start Test
Cold Start Test
Shock Test
(Non-Operating)
Vibration Test
(Non-Operating)
ESD
Room temperature
Test
. Self-recoverable. No hardware failures.
Items
40℃/95%,250Hr
50℃/Dry,250Hr
0℃,250Hr
ON/30 sec. OFF/30sec., 30,000 cycles
65℃/20% RH ,250 hours
-40℃/50% RH ,250 hours
50℃/1 Hr min. power on/off per 5 minutes, 5 times
0℃/1 Hr min. power on/off per 5 minutes, 5 times
220G, 2ms, Half-sine wave
Random vibration, 1.5 G zero-to-peak, 26 to 500 Hz,
30 mins in each of three mutually perpendicular axes.
Contact : ± 8KV/ operation
Air :
25℃, 2000hours, Operating with loop pattern
Product Specification
±15KV / operation
Document version 0.1
Required Condition
Note 1
B121EW01 V5
Note
27/36