K3012 Vishay Telefunken, K3012 Datasheet

no-image

K3012

Manufacturer Part Number
K3012
Description
Optocoupler with Phototriac Output
Manufacturer
Vishay Telefunken
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
K3012P
Quantity:
70 000
Company:
Part Number:
K3012P-X007T
Quantity:
70 000
Optocoupler with Phototriac Output
Description
The K3010P(G) series consists of a phototransistor
optically coupled to a gallium arsenide infrared-emit-
ting diode in a 6-lead plastic dual inline package. The
elements are mounted on one leadframe using a
coplanar technique, providing a fixed distance be-
tween
requirements.
Applications
Circuits for safe protective separation against electri-
cal shock according to safety class II (reinforced
isolation):
Monitors, air conditioners, line switches, solid
state relays, microwaves.
VDE Standards
These couplers perform safety functions according
to the following equipment standards:
Order Instruction
Document Number 83504
Rev. A4, 13–Sep–99
K3010P/ K3010PG
K3011P/ K3011PG
K3012P/ K3012PG
1)
D
D
D
D
D
D
For appl. class I – IV at mains voltage
For appl. class I – III at mains voltage
according to VDE 0884, table 2, suitable for:
VDE 0884
Optocoupler for electrical safety requirements
IEC 950/EN 60950
Office machines (applied for reinforced isolation
for mains voltage
VDE 0804
Telecommunication apparatus and data
processing
IEC 65
Safety for mains-operated electronic and related
household apparatus
G = Leadform 10.16 mm; G is not marked on the body
input
Ordering Code
and
1)
1)
1)
400 V
output
RMS
for
)
highest
600 V
300 V
safety
CTR Ranking
< 15 mA
< 10 mA
< 5 mA
Note: Pin 5 must not be connected
A (+) C (–)
www.vishay.de FaxBack +1-408-970-5600
K3010P(G) Series
~
6
1
2
5
Vishay Telefunken
nc
14827
~
4
3
Remarks
1 (9)

Related parts for K3012

K3012 Summary of contents

Page 1

... Safety for mains-operated electronic and related household apparatus Order Instruction Ordering Code 1) K3010P/ K3010PG 1) K3011P/ K3011PG 1) K3012P/ K3012PG Leadform 10.16 mm not marked on the body Document Number 83504 Rev. A4, 13–Sep–99 highest safety 300 V 600 V Note: Pin 5 must not be connected CTR Ranking < ...

Page 2

... K3010P(G) Series Vishay Telefunken Features Approvals: D BSI 41003 60095 (BS 415 60950 (BS 7002), Certificate number 7081 and 7402 D FIMKO (SETI): EN 60950, Certificate number 12398 D Underwriters Laboratory (UL) 1577 recognized, file number E-76222 D VDE 0884, Certificate number 94778 VDE 0884 related features: ...

Page 3

... Symbol Min 250 DRM (dv/dt (dv/dt) 0.1 crq Type Symbol W = 150 K3010P( K3011P( K3012P( 10813 and dv/dt cr crp K3010P(G) Series Vishay Telefunken Typ. Max. Unit 1.25 1 Typ. Max. Unit V 1 ...

Page 4

... K3010P(G) Series Vishay Telefunken dv/dt Highest value of the “rate of rise of off-state voltage” which does not cause any switching from the cr off-state to the on-state dv/dt Highest value of the “rate of rise of communicating voltage” which does not switch on the device again, ...

Page 5

... C T amb (construction test only) V IOTM IOWM V IORM 0 125 150 t 1 13930 Figure 5. Test pulse diagram for sample test according to K3010P(G) Series Vishay Telefunken Value Unit 130 mA Value Unit 600 mW Value Unit 6 kV ° C 150 Min. Typ. Max. Unit 1.6 ...

Page 6

... K3010P(G) Series Vishay Telefunken Typical Characteristics 400 Coupled device 300 Phototransistor 200 IR-diode 100 – Ambient Temperature ( 11701 amb Figure 6. Total Power Dissipation vs. Ambient Temperature 1000.0 100.0 10.0 1.0 0.1 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 V – Forward Voltage ( 11862 F Figure 7. Forward Current vs. Forward Voltage 1 ...

Page 7

... Type XXXXXX 918 Date Code 0884 (YM Coupling Company System Logo Indicator Figure 12. Marking example Dimensions of K301. Document Number 83504 Rev. A4, 13–Sep–99 Production Location Safety Logo 15090 K3010P(G) Series Vishay Telefunken 14771 www.vishay.de FaxBack +1-408-970-5600 7 (9) ...

Page 8

... K3010P(G) Series Vishay Telefunken Dimensions of K301 www.vishay.de FaxBack +1-408-970-5600 8 (9) 14770 Document Number 83504 Rev. A4, 13–Sep–99 ...

Page 9

... Parameters can vary in different applications. All operating parameters must be validated for each customer application by the customer. Should the buyer use Vishay Telefunken products for any unintended or unauthorized application, the buyer shall indemnify Vishay Telefunken against all claims, costs, damages, and expenses, arising out of, directly or indirectly, any claim of personal damage, injury or death associated with such unintended or unauthorized use ...