Description
HIGH TEMPERATURE UP COMPATIBLE 12-BIT A/D CONVERTER
Manufacturer
Honeywell
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HT574
Manufacturer:
TI
Quantity:
61
Part Number:
HT574
Manufacturer:
NS
Quantity:
266
www.DataSheet4U.com
HTMOS
HIGH TEMPERATURE P COMPATIBLE
12-BIT A/D CONVERTER
FEATURES
The HT574 is a general purpose, 12-bit successive approxi-
mation A/D converter intended for applications with an
extremely wide operating temperature range. Fabricated
with Honeywell’s dielectrically isolated high temperature
(HTMOS™) process, it is designed specifically for severe
high-temperature applications.
The HT574 includes a switched capacitor, digital-to-analog
converter, internal reference, comparator, successive ap-
proximation register, sample and hold, oscillator and archi-
• Specified Over -55 to +225 C
• Includes On-Chip Clock, Reference,
• 11-Bit Linearity
• 10 s Maximum Conversion, Including Acquisition
• Hermetic 28-Lead Ceramic DIP
GENERAL DESCRIPTION
28-LEAD PACKAGE
Solid State Electronics Center • 12001 State Highway 55, Plymouth, MN 55441 • (800) 323-8295 • http://www.ssec.honeywell.com
P Interface and Sample/Hold
TM
High Temperature Products
Ceramic
A
L
Body
Q
1
b2
Reading
(width)
on Lid
Right
D
b
(pitch)
e
S2
E
S1
APPLICATIONS
• Down-Hole Oil Well
• Avionics
• Turbine Engine Control
• Industrial Process Control
• Nuclear Reactor
• Electric Power Conversion
• Heavy Duty Internal Combustion Engines
tecture which allows it to be used with minimal external
components. Tristate output buffers and digital control pins
are also provided for microprocessor interfacing. Analog
input signal ranges of 0 to +10V, 0 to +20V, or 5V may be
selected from the internal resistor scaling network.
The HT574 provides 12-bit conversions in 10 s over the
entire -55 to +225 C temperature range. Typically, parts will
operate up to +300 C for a year, with derated performance.
All parts are burned in at 250 C to eliminate infant mortality.
C
eA
All dimensions in inches
A
b
b2
C
D
E
e
eA
L
Q
S1
S2
0.175 (max)
0.018 ± 0.002
0.050 (typ)
0.010 to 0.002
1.400 ± 0.014
0.594 ± 0.010
0.100 ±0.005
0.600 ±0.010
0.125 to 0.175
0.050 ±0.010
0.005 (min)
0.005 (min)
Advance Information
HT574

Related parts for HT574

HT574 Summary of contents

Page 1

... Analog input signal ranges +10V +20V may be selected from the internal resistor scaling network. The HT574 provides 12-bit conversions over the entire -55 to +225 C temperature range. Typically, parts will operate up to +300 C for a year, with derated performance. ...

Page 2

... HT574 FUNCTIONAL DIAGRAM 2 12_N8 3 NCS 4 Ao CONTROL 5 R_NC VREF_OUT (5.0V) 1 VTRIM 10 VREF_IN (5.0V) 14 20V_IN 13 10V_IN 12 BIP_OFF PINOUT DIAGRAM 1 VLOGIC (+5V) 12_N8 2 3 NCS R_NC VDD (+10V) VREF_OUT 8 9 AGND 10 VREF_IN 11 VTRIM BIP_OFF 12 10V_IN 13 20V_IN 14 TIMING & OSC VBG REF COMP 2.5K VREF = 5V ...

Page 3

... Tmin to Tmax Adjustable to zero Adjustable to zero No adjustment at +25 C, Tmin to Tmax Using internal reference, Tmin to Tmax Max change in full scale calibration VDD = 10V, VLOGIC = 5 V Sink or source 3 HT574 Temperature ranges = -55 to +225 C, VDD = 10.0V 10% Typical @ +25 C, Vlogic = +5V, unless otherwise specified Typ Min Max ...

Page 4

... HT574 DIGITAL CHARACTERISTICS Parameter Logic Inputs (CE, NCS, R_NC, Ao, 12_N8) Logic "1" Logic "0" Current Capacitance Logic Outputs (DB11-DBO, STS) Logic "0" Logic "1" Leakage Capacitance READ MODE AC TIMING CHARACTERISTICS Symbol Parameter tDD Access Time from CE tHD Data Valid after CE Low ...

Page 5

... High Impedance DB11-DB0 Temperature ranges = -55 to +225 C, VDD = 10.0V 10% Typical @ +25 C, Vlogic = +5V, unless otherwise specified Conditions (1) Including Acquisition Tmin to Tmax Tmin to Tmax READ MODE TIMING DIAGRAM CE NCS R_NC Ao STS tC DB11-DB0 5 HT574 Typical Min Max Units 200 ...

Page 6

... HT574 STAND ALONE MODE TIMING CHARACTERISTICS Symbol Parameter tHRL Low R_NC Pulse Width tDS STS Delay from R_NC tHDR Data Valid after R_NC Low tHS STS Delay after Data Valid tHRH High R_NC Pulse Width tDDR Data Access Time SAMPLE AND HOLD CHARACTERISTICS ...

Page 7

... Note offset adjustment is required, BIP_OFF can be tied directy to AGND (0 volts). BIPOLAR INPUT CONNECTIONS Open VIN (±5V) Range BIP_OFF VREF_OUT VREF_IN 14 10K VIN (0 TO 5V) 5K REF OUT = 5V 8 VREF = 5V 2. 10K 13 5K VIN ( REF OUT = 5V 8 VREF = 5V 2. HT574 VBG REF 11 VTRIM VBG REF 11 VTRIM ...

Page 8

... HT574 TRUTH TABLE FOR HT574 CONTROL Case CE NCS ABSOLUTE MAXIMUM RATINGS (1) VDD to Analog Common ........................................................................................................................... 0V to +12.5V VLOGIC to Digital Common ........................................................................................................................... 0V to +7V Analog Common to Digital Common ....................................................................................................................... 1V Control Inputs (CE, NCS, 12_N8, Ao, R_NS) to Digital Common............................................ -0.5V to VLOGIC +0.5V Analog Inputs (VREF_IN, BIP_OFF, 10V_IN) to Analog Common ...