USB2514I SMSC Corporation, USB2514I Datasheet - Page 11

no-image

USB2514I

Manufacturer Part Number
USB2514I
Description
Industrial Temperature Rated USB 2.0 High-Speed 4-Port Hub Controller
Manufacturer
SMSC Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
USB2514I-AEZG
Manufacturer:
NXP
Quantity:
3 000
Part Number:
USB2514I-AEZG
Quantity:
2 457
Part Number:
USB2514I-AEZG
Quantity:
50
Part Number:
USB2514I-HZH
Manufacturer:
Standard
Quantity:
3 763
Industrial Temperature Rated USB 2.0 High-Speed 4-Port Hub Controller
Datasheet
SMSC USB2514i
PRTPWR_POL
OCS[4:1]_N
SYMBOL
36 QFN
n/a
21
19
17
13
Table 3.1 USB2514 Pin Descriptions (continued)
48 QFN
38
28
26
20
16
BUFFER
TYPE
IPU
IPU
DATASHEET
11
BOOST[1:0], If this strap is enabled by package and
configuration settings (see
sampled at RESET_N negation to determine if all PHY
ports (upstream and downstream) operate at a normal
or boosted electrical level. Also, the active state of the
LEDs will be determined as follows:
See for BOOST values:
Boost_Up"
Boost_4:0".
BOOST[1:0] = BOOST_IOUT[1:0]
BOOST[1:0] = ‘00’,
LED_B2_N is active high,
LED_B1_N is active high.
BOOST[1:0] = ‘01’,
LED_B2_N is active high,
LED_B1_N is active low.
BOOST[1:0] = ‘10’,
LED_B2_N is active low,
LED_B1_N is active high.
BOOST[1:0] = ‘11’,
LED_B2_N is active low,
LED_B1_N is active low.
Port Power Polarity strapping
Port Power Polarity strapping determination for the
active signal polarity of the [4:1]PRTPWR pins.
While RESET_N is asserted, the logic state of this pin
will (through the use of internal combinatorial logic)
determine the active state of the [4:1]PRTPWR pins in
order to ensure that downstream port power is not
inadvertently enabled to inactive ports during a
hardware reset.
When RESET_N is negated, the logic value will be
latched internally, and will retain the active signal polarity
for the PRTPWR[4:1] pins.
‘1’ = PRTPWR[4:1]_P/N pins have an active ‘high’
polarity
‘0’ = PRTPWR[4:1]_P/N pins have an active ‘low’
polarity
Warning: Active Low port power controllers may glitch
the downstream port power when system power is first
applied. Care should be taken when designing with
active low components!
Note:
Over Current Sense
Input from external current monitor indicating an over-
current condition.
{Note: Contains internal pull-up to 3.3V supply}
package, the hub will support active high
power controllers only!
If PRTPWR_POL is not an available pin on the
and
Section 4.3.1.27, "Register F8h:
DESCRIPTION
Section 4.3.1.26, "Register F6h:
Table
3.2), this pin will be
Revision 1.98 (11-19-07)