IMP706 IMP Inc, IMP706 Datasheet
IMP706
Available stocks
Related parts for IMP706
IMP706 Summary of contents
Page 1
... The family offers several functional options. Each device generates a reset signal during power-up, power-down and during brownout conditions. A reset is generated when the supply drops below 4.65V (IMP705/707/813L) or 4.40V (IMP706/708). For 3V power supply applications, refer to the IMP705P/R/S/T data sheet. In addition, the IMP705/706/813L feature a 1.6 second watchdog timer. The IMP707/708 have both active-HIGH and active-LOW reset outputs but no watchdog function ...
Page 2
... NC GND PFI PFO PFI Ordering Information IMP705CPA IMP705CSA IMP705CUA IMP705C/D IMP705EPA IMP705ESA IMP706ESA IMP706CPA IMP706CSA IMP706CUA IMP706C/D IMP706EPA IMP706ESA IMP707CPA IMP707CSA IMP707CUA IMP707C/D IMP707EPA IMP707ESA IMP708CPA IMP708CSA IMP708CUA IMP708C/D IMP708EPA IMP708ESA IMP813LCPA IMP813LCSA IMP813LCUA IMP813LC/D IMP813LEPA IMP813LESA RESET ...
Page 3
... IMP, Inc. © Operating Temperature Range IMP705E/706E/707E/708E/813LE . . . . . . . –40°C to 85°C + 0.3V) IMP706C/707C/708C/813LC . . . . . . . . . . . 0°C to 70°C CC Storage Temperature Range . . . . . . . . . . . . . . –65°C to 160°C Lead Temperature Soldering(10 sec 300°C Note: 1. The input voltage limits on PFI and MR can be exceeded if the input current is less than 10mA. ...
Page 4
... Active-LOW reset output. Pulses LOW for 200ms when triggered, and stays low whenever V CC the reset threshold (IMP705: 4.65V, IMP705J: 4.00V, IMP706: 4.40V). RESET remains LOW for 200ms after V rises above the RESET threshold goes from LOW to HIGH. A watchdog timeout will not trigger RESET unless WDO is connected to MR ...
Page 5
RESET/RESET Operation The RESET/RESET signals are designed to start a µP/µ known state or return the system to a known state. The IMP707/708 have two RESET outputs, one active-HIGH RESET and one active-LOW RESET output. The IMP813L has ...
Page 6
Application Information Ensuring That RESET is Valid Down to V When V falls below 1.1V, the IMP705-708 RESET output no CC longer pulls down; it becomes indeterminate. To avoid the possi- bility that stray charges build up and force RESET ...
Page 7
Monitoring Voltages Other Than V The IMP705-708 can monitor voltages other than V Power Fail circuitry resistive divider is connected from the voltage to be monitored to the Power Fail input, PFI, the PFO (output) will go LOW ...
Page 8
Package Dimensions 0.10mm e 0.004in ––––– A1 0.015 A2 0.115 0.014 b2 ...
Page 9
IMP, Inc. Corporate Headquarters 2830 N. First Street San Jose, CA 95134-2071 Tel: 408-432-9100 Tel: 800-438-3722 Fax: 408-434-0335 e-mail: info@impinc.com http://www.impweb.com The IMP logo is a registered trademark of IMP, Inc. All other company and product names are trademarks of ...