M220Z3-L03 Chi Mei, M220Z3-L03 Datasheet - Page 5

no-image

M220Z3-L03

Manufacturer Part Number
M220Z3-L03
Description
TFT LCD Module
Manufacturer
Chi Mei
Datasheet
www.DataSheet.co.kr
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Note (1) Temperature and relative humidity range is shown in the figure below.
Note (2) The temperature of panel surface should be 0 ºC Min. and 60 ºC Max.
Note (3) 11 ms, half-sine wave, 1 time for ± X, ± Y, ± Z.
Note (4) 10 ~ 300 Hz, sweep rate 10 min / cycle , 30 min for X,Y,Z axis
Note (5) Upon the Vibration and Shock tests, the fixture used to hold the module must be firm and rigid
Storage Temperature
Operating Ambient Temperature
Shock (Non-Operating)
Vibration (Non-Operating)
LCD Cell Life Time
-40
(a) 90% RH Max. (Ta ≦ 40 ºC).
(b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation.
enough to prevent the module from twisting or bending by the fixture.
Item
-20
Relative Humidity (%RH)
100
80
60
40
20
90
10
www.speclcd.com
www.speclcd.com
0
Symbol
Operating Range
Temperature (ºC)
L
S
V
T
T
CELL
NOP
NOP
OP
ST
Storage Range
20
5 / 25
50,000
Min.
-20
0
-
-
40
Value
Max.
+60
+50
50
1
-
60
Issued Date: Mar. 4, 2008
Model No.: M220Z3-L03
Doc No.:
Unit
Hrs
ºC
ºC
G
G
80
Tentative
(1), (2)
(3), (5)
(4), (5)
Version 0.0
MTBF
based
Note
(1)
Datasheet pdf - http://www.DataSheet4U.net/