LTC1000-S LEM, LTC1000-S Datasheet

no-image

LTC1000-S

Manufacturer Part Number
LTC1000-S
Description
Current Transducer
Manufacturer
LEM
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LTC1000-SF
Quantity:
4
www.DataSheet4U.com
Current Transducer LTC 1000-S
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
I
I
Î
R
I
K
V
I
X
I
I
t
di/dt
f
T
T
R
m
Notes :
LEM
PN
P
SN
C
OT
O
r
P
A
S
C
M
N
L
G
S
Electrical data
Accuracy - Dynamic performance data
General data
Primary nominal r.m.s. current
Primary current, measuring range @ ± 24 V
Max overload not measurable
Measuring resistance
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
Overall accuracy @ I
Linearity error
Offset current @ I
Thermal drift of I
Response time
di/dt accurately followed
Frequency bandwidth (- 1 dB)
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @ T
Mass
Standards
1)
2)
With a di/dt of > 5 A/µs
With a di/dt of 100 A/µs.
with ± 15 V
with ± 24 V
2)
O
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
@ 90 % of I
@ I
P
= 0, T
PN
PN
, T
, T
A
A
A
= 25°C
@ ± 1000 A
@ ± 1200 A
@ ± 1000 A
@ ± 2000 A
= 25°C
= - 40°C .. + 85°C
PN
A
= 85°C
- 40°C .. + 85°C
max
max
max
max
1000
0 .. ± 2400
10 / 10
R
200
1 : 5000
± 15 .. 24
< 30
< ± 0.4
< ± 1
< 0.1
< 1
> 100
DC .. 100
- 40 .. + 85
- 45 .. + 90
44
750
EN 50155 : 2001
0
0
0
0
± 0.5
± 1
Max
M min
(@ ± 24 V)
R
15
50
M max
7
7
1)
+ I
kA/ms
S
A/µs
kHz
mA
mA
mA
mA
µs
°C
°C
%
%
%
A
A
V
g
I
Features
Advantages
Applications
Application Domain
PN
Closed loop (compensated) current
transducer using the Hall effect
Insulated plastic case recognized
according to UL 94-V0
Railway equipment.
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Traction
=
1000 A
w w w .lem.com
060615/2
Page 1/4

Related parts for LTC1000-S

LTC1000-S Summary of contents

Page 1

... Secondary coil resistance @ Mass Standards Notes : 1) With a di/dt of > 5 A/µs 2) With a di/dt of 100 A/µs. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. LEM 1000 0 .. ± 2400 ± 1000 A 0 max @ ± 1200 A ...

Page 2

... Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. LEM 13.4 3) 1.5 4) > ...

Page 3

... Mechanical characteristics General tolerance Fixing the transducer Recommended fastening torque Primary through-hole Connection of secondary Recommended fastening torque LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. LEM (in mm 0.0394 inch) Connection Remarks ± ...

Page 4

... Feet fixing Kit *** R.m.s. voltage value for partial discharge extinction depends on the busbar. Refer to the datasheet of the corresponding product. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. LEM References 93.34.61.100.0 including all the necessary for its mounting * 93 ...

Related keywords