6.2 Recommend CCFL inverter:
6.1 OPTICAL CHARACTERISTICS OF
Note 6:Absolute maximum ratinge voltage of CFL cable for this module is as follows.
Note 1:Please design your lamp driving circuit (inverter) according to the above specifications.
Note 2:Starting discharge voltage is increased when LCM is operating at lower temperature.
Note 3:Average life time of CFL will be decreased when LCM is operating at lower temperature.
Note 4:Under lower driving frequency of an inverter, a certain backlight system(CFL & CFL
Note 5: When IL is over 3.0mA, it may cause uneven contrast near CFL location, due to heat
Note 7: We suggest that the lamp current can not be lower than the standard of CAS
Note 8:The brightness of the CFL in this LCM may deteriorate after the long-hour use under
Note 9:Except at starting up.
TDK L10L operation voltage +12V , 300mA
TDK L10A operation voltage +5V , 600mA
Lamp Current (1Lamp)(Note 7)
Starting discharge Voltage
Please check the characteristics of your inverter before applying to your set.
VCF side:2Kv
This inverter design shall not exceed the rated voltage.
set, or it will cause low brightness.
5 minutes or more.
ICFL=1.25mA. However, it will recover when the CFL is lighted at ICFL=2.0mA min.
reflection sheet) may generate a sound noise. Before designing the inverter, please
consider the driving frequency and the noise.
dispersion from CFL.
VSS side:300V
Lamp Voltage
Frequency
ITEM
(Note 2)
Symbol
VS
VL
fL
IL
(Note 9)
Min.
250
595
0.5
50
Typ.
1.25
280
--
--
CCFL BACKIGHT
Max.
310
2.0
--
--
Ta=25°C
Vrms
Vrms
Unit
KHz
mA