b32692a6103k189 EPCOS AG, b32692a6103k189 Datasheet

no-image

b32692a6103k189

Manufacturer Part Number
b32692a6103k189
Description
Film Capacitors Metallized Polypropylene Film Capacitors Mfp
Manufacturer
EPCOS AG
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
B32692A6103K189
Manufacturer:
TDK-EPCOS
Quantity:
30 000
Film Capacitors
Metallized Polypropylene Film Capacitors (MFP)
Series/Type:
Date:
© EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
B32692 ... B32694
May 2009

Related parts for b32692a6103k189

b32692a6103k189 Summary of contents

Page 1

... Film Capacitors Metallized Polypropylene Film Capacitors (MFP) Series/Type: B32692 ... B32694 Date: May 2009 © EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. ...

Page 2

Metallized polypropylene film capacitors (MFP) High pulse (wound) Typical applications High-frequency sinusoidal AC loads Electronic ballasts Ignition devices Climatic Max. operating temperature: 110 C Climatic category (IEC 60068-1): 55/100/56 Construction Dielectric: polypropylene (PP) Film metallized on one side and metal ...

Page 3

Dimensional drawings Lead spacing Lead diameter 0 15.0 0.8 22.5 0.8 27.5 0.8 Please read Cautions and warnings and Important notes at the end of this document. High pulse (wound) Detail of double crimped version Type B32692 B32693 ...

Page 4

B32692 ... B32694 High pulse (wound) Overview of available types Lead spacing 15.0 mm Type B32692 Page DC) 630 1000 1250 1600 2000 630 1250 1600 2000 2500 630 1250 1600 2000 AC) 300 ...

Page 5

Ordering codes and packing units (lead spacing 15 mm Max. dimensions R RMS kHz 630 300 2.2 6.0 11.5 3.3 6.0 11.5 4.7 6.0 11.5 6.8 ...

Page 6

B32692 High pulse (wound) Ordering codes and packing units (lead spacing 15 mm Max. dimensions R RMS kHz 1600 450 1.0 6.0 11.5 1.5 6.0 11.5 ...

Page 7

Ordering codes and packing units (lead spacing 22.5 mm Max. dimensions R RMS kHz 630 300 22 6.5 12.5 33 7.0 15.0 47 8.0 17.0 68 ...

Page 8

B32693 High pulse (wound) Ordering codes and packing units (lead spacing 22.5 mm Max. dimensions R RMS kHz 2000 500 2.2 7.0 14.0 3.3 7.0 14.0 ...

Page 9

Ordering codes and packing units (lead spacing 27.5 mm Max. dimensions R RMS kHz 630 300 100 9.5 150 12.0 220 13.5 330 16.0 1250 450 33 ...

Page 10

B32692 ... B32694 High pulse (wound) Technical data Operating temperature range Dissipation factor tan (upper limit values) Insulation resistance R ins rel. humidity 65% (minimum as-delivered values) DC test voltage Category voltage V C ...

Page 11

Characteristic voltages 630 1000 1250 1600 2000 2500 Please read Cautions and warnings and Important notes at the end of this document. High pulse (wound 300 ...

Page 12

B32692 ... B32694 High pulse (wound) Pulse handling capability "dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal voltages, expressed "k " represents the maximum permissible pulse characteristic of the waveform applied to ...

Page 13

Impedance Z versus frequency f (typical values) Please read Cautions and warnings and Important notes at the end of this document. B32692 ... B32694 High pulse (wound) Page ...

Page 14

B32692 High pulse (wound) Permissible AC voltage V RMS For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 15 mm 630 V DC/300 V AC 1250 V DC/450 V AC Please read Cautions and ...

Page 15

Permissible AC voltage V RMS For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 15 mm 2000 V DC/500 V AC Please read Cautions and warnings and Important notes at the end of this ...

Page 16

B32693 High pulse (wound) Permissible AC voltage V RMS For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 22.5 mm 630 V DC/300 V AC 1600 V DC/450 V AC Please read Cautions and ...

Page 17

Permissible AC voltage V RMS For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 22.5 mm 2500 V DC/750 V AC Please read Cautions and warnings and Important notes at the end of this ...

Page 18

B32694 High pulse (wound) Permissible AC voltage V RMS For T >90 C, please refer to "General technical information", section 3.2.3. A Lead spacing 27.5 mm 630 V DC/300 V AC 1600 V DC/450 V AC Please read Cautions and ...

Page 19

Mounting guidelines 1 Soldering 1.1 Solderability of leads The solderability of terminal leads is tested to IEC 60068-2-20, test Ta, method 1. Before a solderability test is carried out, terminals are subjected to accelerated ageing (to IEC 60068-2-2, test Ba: ...

Page 20

B32692 ... B32694 High pulse (wound) Immersion depth Shield Evaluation criteria: Visual inspection C/C 0 tan Please read Cautions and warnings and Important notes at the end of this document. 2.0 +0/ 0.5 mm from capacitor body or seating plane ...

Page 21

General notes on soldering Permissible heat exposure loads on film capacitors are primarily characterized by the upper cate- gory temperature T . Long exposure to temperatures above this type-related temperature limit max can lead to changes in the plastic ...

Page 22

B32692 ... B32694 High pulse (wound) 2 Cleaning To determine whether the following solvents, often used to remove flux residues and other sub- stances, are suitable for the capacitors described, refer to the table below: Type Ethanol, isopropanol, n-propanol MKT ...

Page 23

Embedding of capacitors in finished assemblies In many applications, finished circuit assemblies are embedded in plastic resins. In this case, both chemical and thermal influences of the embedding ("potting") and curing processes must be taken into account. Our experience ...

Page 24

B32692 ... B32694 High pulse (wound) Cautions and warnings Do not exceed the upper category temperature (UCT). Do not apply any mechanical stress to the capacitor terminals. Avoid any compressive, tensile or flexural stress. Do not move the capacitor after ...

Page 25

Topic Safety information Soldering Do not exceed the specified time or temperature limits during soldering. Cleaning Use only suitable solvents for cleaning capacitors. 2 "Cleaning" Embedding of When embedding finished circuit assemblies in capacitors in plastic resins, chemical and thermal ...

Page 26

B32692 ... B32694 High pulse (wound) Symbols and terms Symbol English Heat transfer coefficient Temperature coefficient of capacitance C A Capacitor surface area Humidity coefficient of capacitance C C Capacitance C Rated capacitance R C Absolute capacitance change C/C Relative ...

Page 27

Symbol English I (Sinusoidal) alternating current, RMS root-mean-square value i Capacitance drift z k Pulse characteristic 0 L Series inductance S Failure rate Constant failure rate during useful 0 service life Failure rate, determined by tests test P Dissipated power ...

Page 28

B32692 ... B32694 High pulse (wound) Symbol English V Category voltage C V Category AC voltage C,RMS V Corona-discharge onset voltage CD V Charging voltage voltage DC V Fly-back capacitor voltage FB V Input voltage i V ...

Page 29

Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical ...