SA1E Miniature Photoelectric Switches (Built-in Amplifier Type)
6. Installation
Installing the Photoelectric Switch
• Do not install the SA1E photoelectric switches in an area where
∗ Inductive devices or heat source
∗ Extreme vibration or shock
∗ Large amount of dust
∗ Toxic gases
∗ Water, oil, chemicals
∗ Outdoor
• Make sure to prevent sunlight, fluorescent light, and especially the
• Interference prevention allows two SA1E switches to be mounted
• Because the SA1E photoelectric switches are IP67 waterproof,
• Polycarbonate or acrylic resins are used for optical elements. Do
• Tighten the mounting screws (M3) to a torque of 0.5 N·m. Do not
Turn off power to the SA1E Miniature Photoelectric Switches before installation, removal, wiring, maintenance, and inspection.
Failure to turn power off may cause electrical shock or fire hazard.
the switches are subject to the following conditions, otherwise mal-
function and damage may be caused.
fluorescent light of inverters from entering the receiver of the pho-
toelectric switch directly. Keep the through-beam type receiver
away from intense extraneous light.
in close proximity. However, the through-beam type is not
equipped with interference prevention. Maintain appropriate dis-
tance between the switches referring to the lateral displacement
characteristics on pages 15 and 16.
the SA1E can be exposed to water. However, wipe water drops
and smears from the lens and slit using a soft cloth to make sure
of the best detecting performance.
not use ammonia or caustic soda for cleaning, otherwise optical
elements will be dissolved. To remove dust and moisture build-up,
use soft dry cloth.
tighten the mounting screws excessively or hit the switch with a
hammer, otherwise the protection degree cannot be maintained.
Safety Precautions
IDEC CORPORATION (USA)
1175 Elko Drive, Sunnyvale, CA 94089-2209, USA
Tel: +1-408-747-0550 / (800) 262-IDEC (4332)
Fax: +1-408-744-9055 / (800) 635-6246
E-mail: opencontact@idec.com
IDEC CANADA LIMITED
Unit 22-151, Brunel Road, Mississauga, Ontario,
L4Z 1X3, Canada
Tel: +1-905-890-8561, Toll Free: (888) 317-4332
Fax: +1-905-890-8562
E-mail: sales@ca.idec.com
IDEC AUSTRALIA PTY. LTD.
2/3 Macro Court, Rowville, Victoria 3178, Australia
Tel: +61-3-9763-3244, Toll Free: 1800-68-4332
Fax: +61-3-9763-3255
E-mail: sales@au.idec.com
IDEC ELECTRONICS LIMITED
Unit 2, Beechwood, Chineham Business Park,
Basingstoke, Hampshire RG24 8WA, UK
Tel: +44-1256-321000, Fax: +44-1256-327755
E-mail: sales@uk.idec.com
IDEC ELEKTROTECHNIK GmbH
Wendenstrasse 331, 20537 Hamburg, Germany
Tel: +49-40-25 30 54 - 0, Fax: +49-40-25 30 54 - 24
E-mail: service@idec.de
IDEC (SHANGHAI) CORPORATION
Room 608-609, 6F, Gangtai Plaza, No. 700,
Yan'an East Road, Shanghai 200001, PRC
Tel: +86-21-5353-1000, Fax: +86-21-5353-1263
E-mail: idec@cn.idec.com
IDEC (BEIJING) CORPORATION
Room 211B, Tower B, The Grand Pacific Building,
8A Guanghua Road, Chaoyang District,
Beijing 100026, PRC
Tel: +86-10-6581-6131, Fax: +86-10-6581-5119
IDEC (SHENZHEN) CORPORATION
Unit AB-3B2, Tian Xiang Building, Tian’an Cyber Park,
Fu Tian District, Shenzhen, Guang Dong 518040, PRC
Tel: +86-755-8356-2977, Fax: +86-755-8356-2944
Cat. No. EP1155-0 FEBRUARY 2007 14.4DNP PRINTED IN JAPAN
Installing the Reflector
• Use M4 mounting screws for the IAC-R5 reflector and M5 mount-
• Use the M3 self-tapping screw, flat washer, and spring washer to
• While optional reflector mounting bracket IAC-L2 is not supplied
• Reflector IAC-RS1 and IAC-RS2 can be installed directly on a flat
Installing the air blower mounting block SA9Z-A02
• When installing the SA9Z-A02 on the SA1E photoelectric switch,
• Do not use the mounting screw (M3 × 12) supplied with the mount-
• The SA9Z-A02 cannot be used with the through-beam slits (SA9Z-
• The air tube fitting (M5) can be installed to either the top or side.
• Close the unused port using the supplied air supply port plugging
Installing the background suppression (BGS) type
• This sensor can detect objects correctly when the sensor head is
ing screws for the IAC-R6 reflector. Tighten the mounting screws
to a tightening torque of 0.5 N·m maximum. Mounting screws are
not supplied with the switch.
tighten the IAC-R7 reflector to a torque of 0.5 to 0.6 N·m.
with mounting screws or nuts, the IAC-L3 and IAC-L5 are supplied
with mounting screws for mounting the reflector on the bracket.
surface using the adhesive tape attached to the back of the reflec-
tor. Before attaching the reflector, clean the board surface to
ensure secure attachment.
use the attached M3 × 20 mounting screws and tighten to a torque
of 0.5 N·m maximum.
ing bracket (SA9Z-K01) to mount the SA1E photoelectric switches.
S06 to S14).
The air tube is not supplied.
screw and gasket to a tightening torque of 1 to 2 N·m maximum.
The recommended air pressure is 0.1 to 0.3 MPa.
installed perpendicular to the moving object. Install the sensor
head as shown below to minimize sensing errors.
7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan
Tel: +81-6-6398-2571, Fax: +81-6-6392-9731
E-mail: products@idec.co.jp
Correct
Object
Correct
Object
IDEC IZUMI (H.K.) CO., LTD.
Unit 1505-07, DCH Commercial Centre No. 25,
Westlands Road, Quarry Bay, Hong Kong
Tel: +852-2803-8989, Fax: +852-2565-0171
E-mail: info@hk.idec.com
IDEC TAIWAN CORPORATION
8F-1, No. 79, Hsin Tai Wu Road, Sec. 1,
Hsi-Chih, Taipei County, Taiwan
Tel: +886-2-2698-3929, Fax: +886-2-2698-3931
E-mail: service@tw.idec.com
IDEC IZUMI ASIA PTE. LTD.
No. 31, Tannery Lane #05-01, Dragon Land
Building, Singapore 347788
Tel: +65-6746-1155, Fax: +65-6844-5995
E-mail: info@sg.idec.com
Incorrect
Object
(07/03/06)

Related parts for sa1e-tan2c