si2439-a-gm Silicon Laboratories, si2439-a-gm Datasheet - Page 46

no-image

si2439-a-gm

Manufacturer Part Number
si2439-a-gm
Description
V.92 And V.34 Isomodem With Global Daa
Manufacturer
Silicon Laboratories
Datasheet
Si2494/39
46
Notes:
Command
1. When in autobaud mode, \B0, \B1, and \P1 will not be detected automatically. The combination of \B2 and \P3 will be
2. The autobaud feature does not detect this rate.
3. Default is \T9 if a pulldown resistor is connected to the autobaud strap pin; otherwise, the default is \T16.
\Qn
\Q0
\Q2
\Bn
\B0
\B1
\B2
\B3
\B5
\B6
\Nn
\N0
\N2
\N3
\N4
\N5
\Pn
\P0
\P1
\P2
\P3
\$
detected. This is compatible with seven data bits, no parity, two stop bits. Seven data bits, no parity, one stop bit may be
forced by sending AT\T17\B1.
Display AT\ command settings.
Character length will be automatically set in autobaud mode
6N1—six data bits, no parity, one stop bit, one start bit, eight bits total (\N0 only)
7N1—seven data bits, no parity, one stop bit, one start bit, nine bits total (\N0 only)
7P1—seven data bits, parity optioned by \P, one stop bit, one start bit, 10 bits total
8N1—eight data bits, no parity, one stop bit, one start bit, 10 bits total
8P1—eight data bits, parity optioned by \P, one stop bit, one start bit, 11 bits total (\N0 only)
8X1—eight data bits, one escape bit, one stop bit, one start bit, 11 bits total (enables ninth-bit
escape mode)
Asynchronous protocol
Wire mode (no error correction, no compression)
MNP reliable mode. The Si2494/39 attempts to connect with the MNP protocol. If unsuccessful, the
call is dropped.
V.42 auto-reliable—The Si2494/39 attempts to connect with the V.42 protocol. If unsuccess-
ful, the MNP protocol is attempted. If unsuccessful, wire mode is attempted.
V.42 (LAPM) reliable mode (or drop call)—Same as \N3 except that the Si2494/39 drops the call
instead of connecting in MNP or wire mode.
V.42 and MNP reliable mode—The Si2494/39 attempts to connect with V.42. If unsuccessful, MNP
is attempted. If MNP us unsuccessful, the call is dropped.
Parity type will be automatically set in autobaud mode
Even
Space
Odd
Mark
Modem-to-DTE flow control
Disable all flow control—This may only be used if the DTE speed and the VF speed are guaranteed
to match throughout the call.
Use CTS only
Table 13. Extended AT\ Command Set (Command Defaults in Bold)
1
1
Rev. 1.0
Action
1
1

Related parts for si2439-a-gm