efm-1522 Astrodyne Corporation, efm-1522 Datasheet - Page 2

no-image

efm-1522

Manufacturer Part Number
efm-1522
Description
15w Ultraminiature Open Frame Swi Tching Power Supplies
Manufacturer
Astrodyne Corporation
Datasheet
All specifications are typical at nominal input, full load, and 25°C unless other-
wise noted
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ:
OUTPUT SPECIFICATIONS
Voltage and Current
Load Regulation (20%-FL)
Line Regulation, typ
Cross Regulation
Preset Accuracy
DC Voltage Adjust (typ)
Temperature Coefficient
Ripple/Noise
Over Voltage Protection
Over Temp. Protection
Short Circuit Protection
Hold Up Time
DC Output Power
GENERAL SPECIFICATIONS
Isolation
*
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
1 5 W U lt r aminiat ur e O p en Fr a me Swit ch i ng P ower Suppl ies
WWW.ASTRODYNE.COM
These are stress ratings. Exposure of the devices to any of these conditions
90-264 VAC
47-63 Hz
20A @ 115Volts(DC)
40A @ 230Volts(DC)
See Selection Chart
Singles: ±3%,
Duals: ± 3% (EFM-1508: 0.2/0.2%)
Triple: 0.5/ ±0.2%
Singles ± 0.1~1%
Duals ± 0.3~1% (EFM-1508: 0.5/3%)
Triple: 0.5/ ±0.3%
Duals 2% (EFM-1508: 0.5/3%)
Triple: NA/ ±0.1%
Single/Dual 1% (except
EFM-1508: 2/5%)
Triple: 1/ ±5%
± 6% of FS (Primary)
±0.03%/°C
Single/Duals 100mV Pk-Pk, typ
EFM-1508: 50/50mV pk-pk
Triple: 50/ ±50mV pk-pk
Clamp
Latching, recov after cooling and
power restored.
Continuous, self-recovering
20 mS, typ
15 Watts, max
3KVAC Input-Output
2500VAC Input-Ground
1000VAC Output-Ground
Efficiency , typ
Switching Frequency
Safety
EMC
PHYSICAL SPECIFICATIONS
Size
Construction
Weight
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
MTBF
NOTES
1. Ripple and Noise depend upon output voltage as specified per par-
ticular model.
2. Short Circuit Protection is self-recovering when overcurrent condition
is removed.
3. Isolation for up to 1 minute duration.
4.Specified for free-air convection cooling.
5. Minimum load is NOT required for proper operation. However, auxil-
iary outputs should be reduced as a function of primary output minimum
load or load regulation will be higher.
6.Load regulation measured from 20% to full load.
7.Line regulation measured from 90VAC to 264VAC.
8.Preset accuracy measured at nominal load, 120VAC input.
9.O/P noise measured directly at pins/terminals at nom. load, 0.1uF
bypass, pk-pk @20MHz bandwidth.
10. Cross Reg-Duals:Measured at nom. load with the other output varied
between 60% and 100% inom.
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
Sindle/Dual 75%~78% (EFM-1508: 74%)
Triple: EFM-1509: 70%
100Khz, (fixed, typical)
UL60950-1, EN60950-1
EN55022
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
EFM-1511: 71%
1.77” x 2.64” x 0.91”
Open Frame
2.5oz (70g)
0 to +40°C (See Derate)
-25 to +71°C
0 to + 95%, non-cond
(Mil Std 217, 25°C)
E F M 1 5
*
*
559,000 Hrs
s e r i e s